Bosch Appliances FW5.50 Cameras with alarm and relay I/O, System Log / Event Log, Pre-position

Page 16

16 en Operation via the browser

Camera Browser Interface

 

 

Pre-position

To move the camera to a pre-position, click one of the buttons numbered one to six.

To store the current position of the camera in a pre-position:

1.Position the camera.

2.Enter a pre-position number.

3.Click Set.

3.1.4Cameras with alarm and relay I/O

Depending on the configuration of the unit, the alarm input and the relay output are displayed in the Digital I/O panel next to the camera image.

The alarm symbol is for information and indicates the input status of the alarm input:

Active 1 = Symbol lights

Active 0 = Symbol not lit.

The camera relay allows the operation of an external device (for example, a light or a door opener).

To operate, click the relay symbol.

– The symbol is red when the relay is activated.

3.1.5System Log / Event Log

The System Log field contains information about the operating status of the camera and the connection.

Events such as the triggering or the end of alarms are shown in the Event Log field.

To view, filter and save these messages to a file, click in the top right-hand corner.

To clear the log, click in the top right-hand corner of the relevant field.

AM18-Q0611 v5.50 2012.03

Software manual

Bosch Security Systems

Image 16
Contents Camera Browser Interface Page Table of Contents Advanced General Settings Web InterfaceEncoder Settings CameraAlarm RecordingSetting up VCA Interfaces NetworkService Browser connection System requirementsPassword protection in camera Establishing the connectionProtected network 192.168.0.1Settings System OverviewLivepage RecordingsOperation via the browser Image selectionStatus icons Cameras with PTZ control Motion flagStorage discovery Pan and tiltSystem Log / Event Log Cameras with alarm and relay I/OPre-position Recording video sequences Saving snapshotsRunning recording program Audio communication Processor loadSelecting Recordings Export to FTPControl buttons Controlling playbackSlide control Bookmarks Configuration Menu Settings OverviewBasic Mode Advanced Mode Making Changes NavigationSaving changes Basic Mode Device AccessPassword NamingPassword Confirm passwordDate/Time Device date, time and zoneClick Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewAdvanced General Settings Identification1 ID ISCSI Initiator extensionPassword Confirm passwordDate format Device date / Device timeDevice time zone Daylight saving timeTime server IP address Time server typeAlarm mode stamping Display StampingCamera name stamping Time stampingAlarm message Video watermarkingWeb Interface AppearanceLivepage Functions Show system log Allow snapshotsAllow local recording Frame only streamLogging Save event logSave system log File for event logInstaller Menu CameraPicture Settings White balance2 Day/Night Encoder Settings Pixel Counter Select G.711, L16 or AAC* as the audio Recording formatEncoder Settings Pre-defined profiles Encoder ProfileChanging a profile Standard definition video resolution Profile nameTarget bit rate Maximum bit rateExpert Settings Default 1 H.264 settings Select H.264 SettingsEncoder Streams PreviewJpeg stream Recording Storage Management Device managerRecording media ISCSI MediaActivating and configuring storage media Formatting storage media Deactivating storage mediaRecording Profiles Stream profile settingsRecording includes Recording track selection Alarm recordingStandard recording Alarm triggers Motion/Audio alarm Video loss alarmRetention Time Weekdays Recording SchedulerHolidays Activate recording Profile namesRecording status Recording Status Alarm Alarm ConnectionsVideo transmission StreamRemote port Video outputAuto-connect SSL encryptionAudio Video Content Analyses VCA Audio Alarm Alarm E-Mail Attach Jpeg from camera Destination addressSender name Test e-mailSetting up VCA VCA Silent MOTION+VCA Profiles Aggregation time sMotion detector Analysis typeSensitivity Tamper detection Minimum object sizeDebounce time 1 s Selecting the areaTrigger delay s Global change sliderGlobal change Scene too brightScene too noisy Scene too darkReference check Appearing edges VCA Scheduled Deleting Holidays Delay s VCA Event triggeredTrigger Trigger activeInterfaces Alarm inputRelay Network Access NetworkAutomatic IP assignment IP V4 addressIP V6 address DNS server addressHttp browser port Https browser portInterface mode ETH 14.1.8 RCP+ portTelnet support Network MSS ByteEnable DynDNS Network MTU ByteHost name User nameStatus Authentication AdvancedSnmp 14.2.2 1. Snmp host address / 2. Snmp host addressQuality of Service Rtsp portUPnP TCP metadata inputMulticast EnableMulticast Address Streaming PortMulticast packet TTL Jpeg posting FTP PostingFTP server IP V4 filter FTP server passwordPath on FTP server Maintenance ServiceFirmware Configuration SSL certificateMaintenance log Page Bosch Security Systems