Sensitivity

The basic sensitivity of the tamper detection can be adjusted for the environmental conditions to which the camera is subject. The algorithm reacts to the differences between the reference image and the current video image. The darker the observation area, the higher the value that must be selected.

Trigger delay [s]

Set delayed alarm triggering here. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered. This avoids false alarms triggered by short-term changes, for example, cleaning activities in the direct field of vision of the camera.

Global change (slider)

Set how large the global change in the video image must be for an alarm to be triggered. This setting is independent of the sensor fields selected under Select Area. Set a high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm. This option allows detection, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for example.

Global change

Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.

Scene too bright

Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the objective) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

AM18-Q0611 v5.50 2012.03

Software manual

Bosch Security Systems

Image 72
Contents Camera Browser Interface Page Table of Contents Advanced General Settings Web InterfaceEncoder Settings CameraAlarm RecordingSetting up VCA Interfaces NetworkService Browser connection System requirementsPassword protection in camera Establishing the connectionProtected network 192.168.0.1Settings System OverviewLivepage RecordingsOperation via the browser Image selectionStatus icons Cameras with PTZ control Motion flagStorage discovery Pan and tiltCameras with alarm and relay I/O System Log / Event LogPre-position Saving snapshots Recording video sequencesRunning recording program Audio communication Processor loadSelecting Recordings Export to FTPControlling playback Control buttonsSlide control Bookmarks Settings Overview Configuration MenuBasic Mode Advanced Mode Navigation Making ChangesSaving changes Basic Mode Device AccessPassword NamingPassword Confirm passwordDate/Time Device date, time and zoneClick Set and Reboot NetworkIP address Subnet maskEncoder AudioRecording System OverviewAdvanced General Settings Identification1 ID ISCSI Initiator extensionPassword Confirm passwordDate format Device date / Device timeDevice time zone Daylight saving timeTime server IP address Time server typeAlarm mode stamping Display StampingCamera name stamping Time stampingAlarm message Video watermarkingWeb Interface AppearanceLivepage Functions Show system log Allow snapshotsAllow local recording Frame only streamLogging Save event logSave system log File for event logInstaller Menu CameraPicture Settings White balance2 Day/Night Encoder Settings Pixel Counter Select G.711, L16 or AAC* as the audio Recording formatEncoder Settings Encoder Profile Pre-defined profilesChanging a profile Standard definition video resolution Profile nameTarget bit rate Maximum bit rateExpert Settings Default 1 H.264 settings Select H.264 SettingsEncoder Streams PreviewJpeg stream Recording Storage Management Device managerRecording media ISCSI MediaActivating and configuring storage media Formatting storage media Deactivating storage mediaStream profile settings Recording ProfilesRecording includes Alarm recording Recording track selectionStandard recording Alarm triggers Motion/Audio alarm Video loss alarmRetention Time Recording Scheduler WeekdaysHolidays Profile names Activate recordingRecording status Recording Status Alarm Alarm ConnectionsVideo transmission StreamRemote port Video outputSSL encryption Auto-connectAudio Video Content Analyses VCA Audio Alarm Alarm E-Mail Attach Jpeg from camera Destination addressSender name Test e-mailSetting up VCA VCA Silent MOTION+VCA Profiles Aggregation time sAnalysis type Motion detectorSensitivity Tamper detection Minimum object sizeDebounce time 1 s Selecting the areaTrigger delay s Global change sliderGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA Scheduled Deleting Holidays Delay s VCA Event triggeredTrigger Trigger activeAlarm input InterfacesRelay Network Access NetworkAutomatic IP assignment IP V4 addressIP V6 address DNS server addressHttp browser port Https browser portInterface mode ETH 14.1.8 RCP+ portTelnet support Network MSS ByteEnable DynDNS Network MTU ByteHost name User nameStatus Authentication AdvancedSnmp 14.2.2 1. Snmp host address / 2. Snmp host addressQuality of Service Rtsp portUPnP TCP metadata inputEnable MulticastMulticast Address Port StreamingMulticast packet TTL FTP Posting Jpeg postingFTP server FTP server password IP V4 filterPath on FTP server Service MaintenanceFirmware Configuration SSL certificateMaintenance log Page Bosch Security Systems