Bosch Appliances FW5.50 software manual Recording

Page 50

50 en Recording

Camera Browser Interface

 

 

10 Recording

For camera with SD slots, images can be recorded locally to an SD card or to an appropriately configured iSCSI system.

SD cards are the ideal solution for shorter storage times and temporary recordings. They can be used for local alarm recording or for Automatic Network Replenishment (ANR) to improve the overall reliability of video recording.

For long-term authoritative images use an appropriately sized iSCSI system.

Continuous Recording Hours

 

MicroSDHC card capacity

Profiles

 

 

 

 

4 GB

8 GB

16 GB

32 GB

 

 

 

 

 

HD high quality / low latency

1.5 h

3 h

6 h

12 h

 

 

 

 

 

HD low bandwidth

3.5 h

7 h

14 h

28 h

 

 

 

 

 

SD high quality / low latency

5 h

10 h

20 h

40 h

 

 

 

 

 

SD low bandwidth

12 h

24 h

48 h

96 h

 

 

 

 

 

Note:

The recording hours table is only an indication for reference, an actual situation might be different (because of different scenes or networking status for example).

Two recording tracks are available (Recording 1 and Recording 2). The encoder streams and profiles can be selected for each of these tracks for both standard and alarm recordings.

Ten recording profiles are available where these recording tracks can be defined differently. These profiles are then used for building schedules.

A Video Recording Manager (VRM) can control all recording when accessing an iSCSI system. The VRM is an external program for configuring recording tasks for video servers. For further information, contact your local customer service at Bosch Security Systems.

AM18-Q0611 v5.50 2012.03

Software manual

Bosch Security Systems

Image 50
Contents Camera Browser Interface Page Table of Contents Advanced General Settings Web InterfaceEncoder Settings CameraAlarm RecordingSetting up VCA Interfaces NetworkService Browser connection System requirementsProtected network Password protection in cameraEstablishing the connection 192.168.0.1Livepage SettingsSystem Overview RecordingsOperation via the browser Image selectionStatus icons Storage discovery Cameras with PTZ controlMotion flag Pan and tiltPre-position Cameras with alarm and relay I/OSystem Log / Event Log Running recording program Saving snapshotsRecording video sequences Audio communication Processor loadSelecting Recordings Export to FTPSlide control Controlling playbackControl buttons Bookmarks Basic Mode Advanced Mode Settings OverviewConfiguration Menu Saving changes NavigationMaking Changes Password Basic ModeDevice Access NamingDate/Time PasswordConfirm password Device date, time and zoneIP address Click Set and RebootNetwork Subnet maskRecording EncoderAudio System Overview1 ID Advanced General SettingsIdentification ISCSI Initiator extensionPassword Confirm passwordDevice time zone Date formatDevice date / Device time Daylight saving timeTime server IP address Time server typeCamera name stamping Alarm mode stampingDisplay Stamping Time stampingAlarm message Video watermarkingWeb Interface AppearanceLivepage Functions Allow local recording Show system logAllow snapshots Frame only streamSave system log LoggingSave event log File for event logInstaller Menu CameraPicture Settings White balance2 Day/Night Encoder Settings Pixel Counter Select G.711, L16 or AAC* as the audio Recording formatEncoder Settings Changing a profile Encoder ProfilePre-defined profiles Target bit rate Standard definition video resolutionProfile name Maximum bit rateExpert Settings Default Encoder Streams 1 H.264 settingsSelect H.264 Settings PreviewJpeg stream Recording Recording media Storage ManagementDevice manager ISCSI MediaActivating and configuring storage media Formatting storage media Deactivating storage mediaRecording includes Stream profile settingsRecording Profiles Standard recording Alarm recordingRecording track selection Alarm triggers Motion/Audio alarm Video loss alarmRetention Time Holidays Recording SchedulerWeekdays Recording status Profile namesActivate recording Recording Status Alarm Alarm ConnectionsRemote port Video transmissionStream Video outputAudio SSL encryptionAuto-connect Video Content Analyses VCA Audio Alarm Alarm E-Mail Sender name Attach Jpeg from cameraDestination address Test e-mailSetting up VCA VCA Silent MOTION+VCA Profiles Aggregation time sSensitivity Analysis typeMotion detector Debounce time 1 s Tamper detectionMinimum object size Selecting the areaGlobal change Trigger delay sGlobal change slider Scene too brightReference check Scene too darkScene too noisy Appearing edges VCA Scheduled Deleting Holidays Trigger Delay sVCA Event triggered Trigger activeRelay Alarm inputInterfaces Automatic IP assignment Network AccessNetwork IP V4 addressHttp browser port IP V6 addressDNS server address Https browser portTelnet support Interface mode ETH14.1.8 RCP+ port Network MSS ByteHost name Enable DynDNSNetwork MTU Byte User nameStatus Snmp AuthenticationAdvanced 14.2.2 1. Snmp host address / 2. Snmp host addressUPnP Quality of ServiceRtsp port TCP metadata inputMulticast Address EnableMulticast Multicast packet TTL PortStreaming FTP server FTP PostingJpeg posting Path on FTP server FTP server passwordIP V4 filter Firmware ServiceMaintenance Configuration SSL certificateMaintenance log Page Bosch Security Systems