7.2. Equipment Functions

AI-900MF Main Frame

The AI-900MF accommodates the following cards: Up to 2 AI-900MS or AI-900AL Cards (both cards may be mixed), up to 4 AI-900RS Cards, 1 AI-900CO Card, 1 AI-900AF Card, and 1 AI-900TI Card.

The Main Frame has 2 RS-232C ports; one for programming and the other for operation log output.

AI-900MS Master Station Interface Card

The AI-900MS is used for master station connection. Up to 2 master stations can be connected per card, and an external recording device can be connected to each line.

AI-900AL Telephone Interface Card

The AI-900AL is used for connecting telephone sets (in compliance with the FCC Regulation Part 68). Up to 2 telephones can be connected per card, and an external recording device can be connected to each line.

AI-900RS Substation Interface Card

The AI-900RS is used for substation connection. Up to 16 substations can be connected per card. The Substation Interface Card has 2 speech links, one of which also functions as a paging link with the paging input/output connected to an external amplifier.

AI-900CO Outside Line Interface Card

The AI-900CO is used for outside line connection. Up to 2 outside lines can be connected per card, and an external recording device can be connected to each line.

AI-900AF Audio Function Card

The AI-900AF enables Conference, External Amplifier Paging, and External Source Distribution functions. The Audio Function Card has 1 conference link (maximum 4 stations), 1 voice output and 16 control outputs for external amplifier paging, and 1 voice input and 4 control inputs for external source distribution.

AI-900TI Tie-Line Interface Card

The AI-900TI is used to interconnect multiple exchanges. The Tie-Line Interface Card can connect up to 4 links made up by 1 pair of data lines and 2 pairs of voice lines.

AI-PU200 Power Transformer Unit

The wall-mountable AI-PU200 has 2 20V/2.5A AC outputs. One AI-PU200 unit is required when up to 2 AI-900RS Cards are installed, and 2 AI-PU200 units are required when 3 or more AI-900RS Cards are installed.

AI-YC303 Main Frame Wall Mounting Bracket

The AI-YC303 is used when mounting the main frame on the wall.

AI-PN100B Rack Mount Panel

The AI-PN100B provides side-by-side rack mounting capability for up to 2 AI-PU200 transformer units.

AI-MS900 Master Station

The AI-MS900 can make calls to or receive calls from the substation. It utilizes 2 pairs of twisted cables.

AI-RS150 Substation (Indoor Type)

The AI-RS150 can call and converse with the registered master stations. It utilizes a single-pair shielded cable.

AI-RS160 Substation (Indoor Vandal-Resistant Type)

The AI-RS160 can call and converse with the registered master stations. It utilizes a single-pair shielded cable.

AI-RS170 Substation (Outdoor Vandal-Resistant Type)

The AI-RS170 can call and make converse with the registered master stations. It utilizes a single-pair shielded cable.

AI-RS180 Substation (for Emergency Use)

The AI-RS180 can call and converse with the registered master stations. It has a indicator lamp and a control output channel, and utilizes a single-pair shielded cable.

10

Image 10
Contents Installation Manual Voice Security SystemTable of Contents Speech and Function Tests When mounted on a wall Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in Use Applicable to the exchangeApplicable to the exchange FCC Requirements Industry Canada Requirements Installation Precautions FeaturesGeneral Description System Configuration and Equipment Functions System ConfigurationEquipment Functions AI-900MF Main Frame Nomenclature and Functions Installation and Connection Procedures AI-900MF Main Frame Equipment InstallationRack mounting 55.2 AI-PU200 Power Transformer Unit Wall mounting Dimensional diagram AI-RS150, AI-RS160, AI-RS170 and AI-RS180 SubstationsMaster Station Desk-top mountingBackup Battery Installation AI-900MF Card InstallationBattery replacement Card Installation Wiring Wiring from the Station or Outside LineSupplied Connector Connection View a Station Address SettingAI-900MS Master Station Interface Card Connection Master Station and AI-900MS connectionConnection AI-900MS and AI-MS900 connectionExternal recording device and AI-900MS connection CN3 CN4AI-MS900 Master Station Connection and Adjustment External speaker connectionAI-900AL Telephone Interface Card Connection Telephone and AI-900AL connectionSetting telephones talking volume levels Setting of telephone volume switches on the AI-900AL cardExternal recording device and AI-900AL connection AI-900RS Substation Interface Card Connection Substation and AI-900RS connectionExternal amplifier and AI-900RS connection AI-900CO Outside Line Interface Card Connection Outside line and AI-900CO connectionExternal recording device and AI-900CO connection Amplifier and AI-900AF connection AI-900AF Audio Function Card ConnectionExternal amplifier and AI-900AF connection External sound source and AI-900AF connection External sound sources and AI-900AF connectionTermination resistance setting AI-900TI Tie-Line Interface Card Exchange InterconnectionExchange interconnection by means of AI-900TI Exchange Number Setting Exchange No. settingAI-900MF and power supply connection Direct connection by means of RS-232C Main Frame and PC ConnectionProgramming PC Connection Direct connection by means of RS-232C Programming PCConnection via modem Connection via modem Programming PCOperation Log PC Connection Direct connection by means of RS-232C Operation log PCSystem Programming Connection via modem Operation log PCFunction Test Speech and Function TestsSpeech Test Calls from the substationAccessories SpecificationsAI-900MS Master Station Interface Card AI-900AL Telephone Interface Card AI-900RS Substation Interface CardAI-900CO Outside Line Interface Card AI-900AF Audio Function CardAI-900TI Tie-Line Interface Card AI-YC303 Main Frame Wall Mounting Bracket