Aiphone AI-900 installation manual Installation and Connection Procedures

Page 12

9.INSTALLATION AND CONNECTION PROCEDURES

(1)System Design

Exchange/Station Configuration, Wiring Schedule and Station Numbering Schedule

(2) Equipment Installation

 

Installing the AI-900MF Main Frame in an Equipment Rack or on a Wall

(See p. 13.)

 

 

 

 

 

 

 

 

 

Installing the AI-PU200 Power Transformer in an Equipment Rack or on a Wall

(See p. 15.)

 

 

 

 

 

 

 

 

 

Installing the Substation

(See p. 17.)

 

 

 

 

 

 

 

 

 

Installing the Master Station

(See p. 18.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3) Installing a Card in the AI-900MF Main Frame

 

 

 

 

 

 

Installing the Data Backup Battery

(See p. 19.)

 

 

 

 

 

 

 

 

 

Installing and Connecting Each Card

(See p. 20.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(4) Connecting the Station/Outside Line to Each Exchange Card

 

 

 

 

 

 

AI-MS900 Master Station vs. AI-900MS Card

(See p. 23.)

 

 

• External Recording Device vs. AI-900MS Card

(See p. 25.)

 

 

 

 

 

 

 

 

 

• Telephone vs. AI-900AL Card

(See p. 27.)

 

 

• External Recording Device vs. AI-900AL Card

(See p. 29.)

 

 

 

 

 

 

 

 

 

• Substation vs. AI-900RS Card

(See p. 30.)

 

 

• External Amplifier vs. AI-900RS Card

(See p. 31.)

 

 

 

 

 

 

 

 

 

• Outside Line vs. AI-900CO Card

(See p. 32.)

 

 

• External Recording Device vs. AI-900CO Card

(See p. 33.)

 

 

 

 

 

 

 

 

 

• External Amplifier vs. AI-900AF Card

(See p. 34.)

 

 

• External Recording Device vs. AI-900AF Card

(See p. 35.)

 

 

 

 

 

 

 

 

 

AI-900MF Main Frame vs. AI-PU200 Power Transformer

(See p. 39.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5) Tie-Line Connection (between Exchanges)

 

 

 

 

 

 

AI-900TI vs. AI-900TI

(See p. 36.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(6) Connecting the AI-900MF Main Frame to a PC

 

 

 

 

 

 

Connection to a Programming PC

(See p. 40.)

 

 

 

 

 

 

 

 

 

Connection to an Operation Log PC

(See p. 42.)

 

 

 

 

 

 

 

 

 

 

 

Power

-ON

 

 

 

 

 

 

 

(7) Adjusting the Station and Exchange

 

 

 

 

 

 

 

System Programming (See the "AI-900 SETUP SOFTWARE MANUAL.")

 

 

 

 

 

 

 

 

 

 

Master Station Microphone Sensitivity/Speaker Volume Adjustment

(See p. 26.)

 

 

 

 

 

 

 

 

 

Telephone Volume Adjustment (AI-900AL Card)

(See p. 28.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(8) Speech and Function Tests

 

 

 

 

 

 

 

Speech Test

(See p. 44.)

 

 

 

 

 

 

 

 

 

Function Test

(See p. 44.)

 

 

 

 

 

 

 

 

 

 

 

12

Image 12
Contents Installation Manual Voice Security SystemTable of Contents Speech and Function Tests Safety Precautions Safety Symbol and Message ConventionsWhen mounted on a wall When the Unit is in Use Applicable to the exchangeApplicable to the exchange FCC Requirements Industry Canada Requirements Features Installation PrecautionsGeneral Description System Configuration and Equipment Functions System ConfigurationEquipment Functions AI-900MF Main Frame Nomenclature and Functions Installation and Connection Procedures Equipment Installation AI-900MF Main FrameRack mounting 55.2 AI-PU200 Power Transformer Unit Wall mounting Dimensional diagram AI-RS150, AI-RS160, AI-RS170 and AI-RS180 SubstationsMaster Station Desk-top mountingAI-900MF Card Installation Backup Battery InstallationBattery replacement Card Installation Wiring Wiring from the Station or Outside LineSupplied Connector Connection Station Address Setting AI-900MS Master Station Interface Card ConnectionView a Master Station and AI-900MS connectionConnection AI-900MS and AI-MS900 connectionExternal recording device and AI-900MS connection CN3 CN4AI-MS900 Master Station Connection and Adjustment External speaker connectionAI-900AL Telephone Interface Card Connection Telephone and AI-900AL connectionSetting telephones talking volume levels Setting of telephone volume switches on the AI-900AL cardExternal recording device and AI-900AL connection AI-900RS Substation Interface Card Connection Substation and AI-900RS connectionExternal amplifier and AI-900RS connection AI-900CO Outside Line Interface Card Connection Outside line and AI-900CO connectionExternal recording device and AI-900CO connection AI-900AF Audio Function Card Connection Amplifier and AI-900AF connectionExternal amplifier and AI-900AF connection External sound source and AI-900AF connection External sound sources and AI-900AF connectionTermination resistance setting AI-900TI Tie-Line Interface Card Exchange InterconnectionExchange interconnection by means of AI-900TI Exchange Number Setting Exchange No. settingAI-900MF and power supply connection Main Frame and PC Connection Programming PC ConnectionDirect connection by means of RS-232C Direct connection by means of RS-232C Programming PCConnection via modem Connection via modem Programming PCOperation Log PC Connection Direct connection by means of RS-232C Operation log PCSystem Programming Connection via modem Operation log PCSpeech and Function Tests Speech TestFunction Test Calls from the substationSpecifications AccessoriesAI-900MS Master Station Interface Card AI-900AL Telephone Interface Card AI-900RS Substation Interface CardAI-900CO Outside Line Interface Card AI-900AF Audio Function CardAI-900TI Tie-Line Interface Card AI-YC303 Main Frame Wall Mounting Bracket