Aiphone AI-900 installation manual General Description, Features, Installation Precautions

Page 8

4. GENERAL DESCRIPTION

The AI-900 Security System is a voice communication system that permits calls to be quickly and easily made - even in emergency situations - with the touch of single button. The system can record conversations, and features external equipment sync output and operation log output. These features combine to make the AI-900 an ideal system for voice security applications.

5. FEATURES

Modular construction facilitates installation, maintenance, and system expansion.

Rack- or wall-mountable exchange.

Up to 4 master stations (or commercial telephone sets) and 64 substations can be connected per exchange.

Up to 2 outside telephone (C/O) lines can be connected per exchange.

Station paging (by means of the substation speaker) and external paging functions.

External sound source distribution capability.

Up to 19 paging zones can be established.

Emergency Paging function.

By connecting an external recording device, the conversations at the master station (or telephone set) and at the outside line telephone can be recorded.

Exchange operating log can be transmitted to a PC.

Tie-line possible for up to 16 exchanges.

24 V DC input for connection of backup power supply.

Manual/Automatic Call Forwarding, Conference, Scan Monitor functions.

6. INSTALLATION PRECAUTIONS

To prevent the unit's failure, be sure to switch off its power when inserting or removing the card.

When mounting each card, fully insert it into the Main Frame. After all cards are mounted, secure them with the card fixing bracket.

When the unit gets dirty with dust or oil, wipe down with a soft, dry cloth. Never use a chemically-treated cleaning cloth or volatile liquids, such as benzine and thinner, because the unit's plastic parts may be deformed or its finish discolored.

All units except the AI-RS170 and AI-RS180 Substations are designed exclusively for indoor use. Do not install them outdoors.

The whole system will not operate without power supply.

In areas where broadcasting stations are close by, the system operation may be affected by radio frequency interference.

Keep DC wiring at least 30 cm away from AC wiring. Otherwise, the system may malfunction.

8

Image 8
Contents Installation Manual Voice Security SystemTable of Contents Speech and Function Tests Safety Precautions Safety Symbol and Message ConventionsWhen mounted on a wall When the Unit is in Use Applicable to the exchangeApplicable to the exchange FCC Requirements Industry Canada Requirements General Description FeaturesInstallation Precautions System Configuration and Equipment Functions System ConfigurationEquipment Functions AI-900MF Main Frame Nomenclature and Functions Installation and Connection Procedures Rack mounting Equipment InstallationAI-900MF Main Frame 55.2 AI-PU200 Power Transformer Unit Wall mounting Dimensional diagram AI-RS150, AI-RS160, AI-RS170 and AI-RS180 SubstationsMaster Station Desk-top mountingBattery replacement AI-900MF Card InstallationBackup Battery Installation Card Installation Wiring Wiring from the Station or Outside LineSupplied Connector Connection Station Address Setting AI-900MS Master Station Interface Card ConnectionView a Master Station and AI-900MS connectionConnection AI-900MS and AI-MS900 connectionExternal recording device and AI-900MS connection CN3 CN4AI-MS900 Master Station Connection and Adjustment External speaker connectionAI-900AL Telephone Interface Card Connection Telephone and AI-900AL connectionSetting telephones talking volume levels Setting of telephone volume switches on the AI-900AL cardExternal recording device and AI-900AL connection AI-900RS Substation Interface Card Connection Substation and AI-900RS connectionExternal amplifier and AI-900RS connection AI-900CO Outside Line Interface Card Connection Outside line and AI-900CO connectionExternal recording device and AI-900CO connection External amplifier and AI-900AF connection AI-900AF Audio Function Card ConnectionAmplifier and AI-900AF connection External sound source and AI-900AF connection External sound sources and AI-900AF connectionTermination resistance setting AI-900TI Tie-Line Interface Card Exchange InterconnectionExchange interconnection by means of AI-900TI Exchange Number Setting Exchange No. settingAI-900MF and power supply connection Main Frame and PC Connection Programming PC ConnectionDirect connection by means of RS-232C Direct connection by means of RS-232C Programming PCConnection via modem Connection via modem Programming PCOperation Log PC Connection Direct connection by means of RS-232C Operation log PCSystem Programming Connection via modem Operation log PCSpeech and Function Tests Speech TestFunction Test Calls from the substationAI-900MS Master Station Interface Card SpecificationsAccessories AI-900AL Telephone Interface Card AI-900RS Substation Interface CardAI-900CO Outside Line Interface Card AI-900AF Audio Function CardAI-900TI Tie-Line Interface Card AI-YC303 Main Frame Wall Mounting Bracket