Aiphone installation manual Specifications, AI-900MS Master Station Interface Card, Accessories

Page 45

15. SPECIFICATIONS

[AI-900MF Main Frame]

Power Source

20 V AC, 24 V DC

 

 

 

 

Current Consumption

5.5 A

 

Speech Path Configuration

Time sharing switch (T1 stage)

 

 

 

Serial port

Complies with the RS-232C Standard, D-sub connector (9-pin, female),

 

2 ports

 

Installation Method

Rack- and wall-mountable

 

 

 

 

Other

Real time clock for time control

 

 

Unit's presence/non-presence detection

 

System programming data maintenance

 

Power switch

 

 

 

 

Connection Terminal

Bus connector:

DIN connector (64-pin, female) x 9

 

AI-PU200 connection terminal: 4-pin x 2 (2 AI-PU200s are connectable.)

 

24 V DC input terminal:

4-pin (with grounding terminal)

 

 

 

Operating Temperature

0 – 40°C

 

Finish

Pre-coated steel plate, black, 30% gloss

 

 

Dimensions

420 (w) x 443.7 (h) x 288.3 (d) mm (excluding the rack mounting bracket)

 

 

 

Weight

12.7 kg

 

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

Rack mounting bracket

2

Machine screw (M4 x 10)

6

Cable clip

20

4-pin dedicated connector

3

CR2032 battery

1

Floppy disk (PC setting software)

2

AI-900 operating instructions

1

AI-900 installation manual (this manual) ....

1

AI-900 setup software manual

1

Rack mounting screw

8

Rack mounting washer

8

[AI-900MS Master Station Interface Card]

Power Source

5 V DC, 24 V DC (supplied from the main frame)

 

 

Current Consumption

50 mA (5 V DC), 200 mA (24 V DC)

Supply Power

24 V DC, 80 mA

 

 

 

 

Number of Lines

2 lines

 

 

 

Conversation Recording Output

Audio signal: 0 dB*, unbalanced

 

Control signal: Open collector output, withstand voltage: 24 V DC,

 

control current: 20 mA

 

 

 

Connection Terminal

Main frame connection side:

DIN connector (64-pin, male)

 

Line output:

4-pin x 2

 

Recording audio/control output: 4-pin x 2

 

 

 

Weight

350 g

 

* 0 dB = 1 V

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

4-pin dedicated connector

4

Ferrite clamp SFC-10

2

45

Image 45
Contents Voice Security System Installation ManualTable of Contents Speech and Function Tests Safety Symbol and Message Conventions Safety PrecautionsWhen mounted on a wall When the Unit is in Use Applicable to the exchangeApplicable to the exchange FCC Requirements Industry Canada Requirements Features Installation PrecautionsGeneral Description System Configuration System Configuration and Equipment FunctionsEquipment Functions AI-900MF Main Frame Nomenclature and Functions Installation and Connection Procedures Equipment Installation AI-900MF Main FrameRack mounting 55.2 AI-PU200 Power Transformer Unit Wall mounting AI-RS150, AI-RS160, AI-RS170 and AI-RS180 Substations Dimensional diagramDesk-top mounting Master StationAI-900MF Card Installation Backup Battery InstallationBattery replacement Card Installation Wiring from the Station or Outside Line WiringSupplied Connector Connection AI-900MS Master Station Interface Card Connection Station Address SettingView a Master Station and AI-900MS connectionAI-900MS and AI-MS900 connection ConnectionCN3 CN4 External recording device and AI-900MS connectionExternal speaker connection AI-MS900 Master Station Connection and AdjustmentTelephone and AI-900AL connection AI-900AL Telephone Interface Card ConnectionSetting of telephone volume switches on the AI-900AL card Setting telephones talking volume levelsExternal recording device and AI-900AL connection Substation and AI-900RS connection AI-900RS Substation Interface Card ConnectionExternal amplifier and AI-900RS connection Outside line and AI-900CO connection AI-900CO Outside Line Interface Card ConnectionExternal recording device and AI-900CO connection AI-900AF Audio Function Card Connection Amplifier and AI-900AF connectionExternal amplifier and AI-900AF connection External sound sources and AI-900AF connection External sound source and AI-900AF connectionAI-900TI Tie-Line Interface Card Exchange Interconnection Termination resistance settingExchange interconnection by means of AI-900TI Exchange No. setting Exchange Number SettingAI-900MF and power supply connection Programming PC Connection Main Frame and PC ConnectionDirect connection by means of RS-232C Direct connection by means of RS-232C Programming PCConnection via modem Programming PC Connection via modemDirect connection by means of RS-232C Operation log PC Operation Log PC ConnectionConnection via modem Operation log PC System ProgrammingSpeech Test Speech and Function TestsFunction Test Calls from the substationSpecifications AccessoriesAI-900MS Master Station Interface Card AI-900RS Substation Interface Card AI-900AL Telephone Interface CardAI-900AF Audio Function Card AI-900CO Outside Line Interface CardAI-YC303 Main Frame Wall Mounting Bracket AI-900TI Tie-Line Interface Card