Aiphone AI-900AL Telephone Interface Card, AI-900RS Substation Interface Card

Page 46

[AI-900AL Telephone Interface Card]

Power Source

5 V DC, 15 V DC, 24 V DC (supplied from the main frame)

 

 

Current Consumption

150 mA (5 V DC), 30 mA (15 V DC), 200 mA (24 V DC)

 

 

 

Supply Power

24 V DC, 80 mA

 

 

 

 

Number of Lines

2 lines

 

 

 

Conversation Recording Output

Audio signal: 0 dB*, unbalanced

 

Control signal: Open collector output, withstand voltage: 24 V DC,

 

control current: 20 mA

 

 

 

Selectable Signal Type

DTMF signal

 

 

 

 

Monitoring Function

Line loop detection function

 

 

 

Applicable Terminal

Telephone sets to comply with FCC Part 68

 

 

Control Function

Call signal transmission, audible signal transmission,

 

caller identification signal transmission (Caller ID Function)

 

 

 

Connection Terminal

Main frame connection side:

DIN connector (64-pin, male)

 

Line output:

2-pin x 2

 

Recording audio/control output: 4-pin x 2

 

 

 

Weight

400 g

 

 

 

 

* 0 dB = 1 V

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

2-pin dedicated connector

2

4-pin dedicated connector

2

Ferrite clamp SFC-10

2

[AI-900RS Substation Interface Card]

Power Source

5 V DC, 24 V DC (supplied from the main frame)

 

 

Current Consumption

200 mA (5 V DC), 600 mA (24 V DC)

 

 

Number of Lines

Substation 16 lines

Number of Links

2 links (One of 2 links is also used as a Paging Link.)

 

 

Paging Output

Unbalanced, –20 dB* signals to be sent to a paging amplifier

 

 

Paging Input

Balanced, acceptable signals on the 25 V line output from a paging

 

amplifier

 

 

Conversation Method

Half-duplex conversation by voice-operated switch or simplex

 

conversation by PTT switch

Supply Power

Maximum 1 W per substation

 

 

Other

Call button detection function and speech link control function

 

 

Connection Terminal

Main frame connection side: DIN connector (64-pin, male)

 

Substation connection side: Two-core shielded cable (3-pin) x 16

 

Paging input/paging output: 4-pin

 

 

Weight

550 g

 

 

 

* 0 dB = 1 V

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

3-pin dedicated connector

16

4-pin dedicated connector

1

46

Image 46
Contents Installation Manual Voice Security SystemTable of Contents Speech and Function Tests When mounted on a wall Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in Use Applicable to the exchangeApplicable to the exchange FCC Requirements Industry Canada Requirements Installation Precautions FeaturesGeneral Description System Configuration and Equipment Functions System ConfigurationEquipment Functions AI-900MF Main Frame Nomenclature and Functions Installation and Connection Procedures AI-900MF Main Frame Equipment InstallationRack mounting 55.2 AI-PU200 Power Transformer Unit Wall mounting Dimensional diagram AI-RS150, AI-RS160, AI-RS170 and AI-RS180 SubstationsMaster Station Desk-top mountingBackup Battery Installation AI-900MF Card InstallationBattery replacement Card Installation Wiring Wiring from the Station or Outside LineSupplied Connector Connection View a Station Address SettingAI-900MS Master Station Interface Card Connection Master Station and AI-900MS connectionConnection AI-900MS and AI-MS900 connectionExternal recording device and AI-900MS connection CN3 CN4AI-MS900 Master Station Connection and Adjustment External speaker connectionAI-900AL Telephone Interface Card Connection Telephone and AI-900AL connectionSetting telephones talking volume levels Setting of telephone volume switches on the AI-900AL cardExternal recording device and AI-900AL connection AI-900RS Substation Interface Card Connection Substation and AI-900RS connectionExternal amplifier and AI-900RS connection AI-900CO Outside Line Interface Card Connection Outside line and AI-900CO connectionExternal recording device and AI-900CO connection Amplifier and AI-900AF connection AI-900AF Audio Function Card ConnectionExternal amplifier and AI-900AF connection External sound source and AI-900AF connection External sound sources and AI-900AF connectionTermination resistance setting AI-900TI Tie-Line Interface Card Exchange InterconnectionExchange interconnection by means of AI-900TI Exchange Number Setting Exchange No. settingAI-900MF and power supply connection Direct connection by means of RS-232C Main Frame and PC ConnectionProgramming PC Connection Direct connection by means of RS-232C Programming PCConnection via modem Connection via modem Programming PCOperation Log PC Connection Direct connection by means of RS-232C Operation log PCSystem Programming Connection via modem Operation log PCFunction Test Speech and Function TestsSpeech Test Calls from the substationAccessories SpecificationsAI-900MS Master Station Interface Card AI-900AL Telephone Interface Card AI-900RS Substation Interface CardAI-900CO Outside Line Interface Card AI-900AF Audio Function CardAI-900TI Tie-Line Interface Card AI-YC303 Main Frame Wall Mounting Bracket