Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND | CAUSE | DISPLAY |
|
|
|
LOUD, | FIRE ALARM | FIRE is displayed; zone number of zone in |
INTERRUPTED* |
| alarm is displayed. If a fire alarm is manually |
Keypad & Ext. |
| activated, zone number 95 will be displayed. |
|
| |
|
|
|
LOUD, | BURGLARY/AUDIBLE | ALARM is displayed. Zone number of zone in |
CONTINUOUS* | EMERGENCY ALARM | alarm is also displayed. |
Keypad & Ext. |
|
|
ONE SHORT BEEP | a. SYSTEM DISARM | a. READY indicator light comes on. |
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. Number of the open protection zone displayed. |
Keypad only | WITH AN OPEN ZONE. |
|
| c. BYPASS VERIFY | c. Zone numbers of the bypassed protection |
|
| zones are displayed (one beep is heard for |
|
| each zone displayed). Subsequently, BYPASS |
|
| is displayed. |
|
|
|
ONE SHORT BEEP | a. SYSTEM IS IN TEST MODE | a. Opened zone numbers will appear. |
(once every 40 secs) | b. LOW BATTERY AT A | b. BAT displayed with zone number of |
Keypad only | TRANSMITTER | transmitter. |
| c. SYSTEM WILL AUTOARM | c. No special display. |
| WITHIN 10 MINUTES |
|
|
|
|
TWO SHORT BEEPS | ARM AWAY or MAXIMUM | AWAY is displayed. Red ARMED indicator is lit. |
Keypad only |
|
|
THREE SHORT | a. ARM STAY, | a. STAY or INSTANT is displayed. Red |
BEEPS | INSTANT | ARMED indicator is lit. |
Keypad only |
| b. CHIME displayed; zone number of open |
| b. ZONE OPENED WITH | protection zone will be displayed if the [∗] |
| SYSTEM IN CHIME MODE. | key is pressed. |
RAPID BEEPING | a. TROUBLE | a. CHECK displayed. Zone number of troubled |
Keypad only |
| protection zone is displayed. |
| b. MEMORY OF ALARM | b. FIRE or ALARM is displayed; zone number |
|
| of zone in alarm is displayed |
| c. SYSTEM LOW BATTERY | c. BAT displayed with no zone ID number. |
| d. EXT. SOUNDER WIRING FAIL | d. CHECK 70 is displayed. |
| e. LAST 10 SEC of EXIT DELAY | e. No special display. |
SLOW BEEPING | a. EXIT DELAY WARNING | a. AWAY is displayed. |
Keypad only | b. ENTRY DELAY WARNING | b. Exceeding the entry delay time without |
| ||
|
| disarming causes alarm. |
|
|
|
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.