About The Keypads (Continued)
Fixed-Word Display Keypad
AWAY: | All burglary zones, interior and |
|
|
|
|
|
| |
|
|
| AWAY NIGHT NO AC | |||||
| perimeter, are armed. |
|
|
| ||||
|
|
|
| BYPASS | PHONE TEST | |||
STAY: | Perimeter burglary zones, such as |
|
|
| NOT READY | |||
|
|
| STAY | |||||
ALARM | ||||||||
CHIME BAT | ||||||||
| protected windows and doors, are | FIRE CHECK INSTANT | CANCELED | |||||
| armed. |
|
|
| FA260KP |
| ||
INSTANT: | Entry delay is turned off: |
|
|
| AWAY |
| NO AC | |
|
|
|
|
|
| |||
| Lit with STAY = Instant mode |
|
|
| STAY |
| CHIME | |
| Lit with AWAY = Maximum mode |
| ALARM | INSTANT |
| BAT | ||
|
| CHECK BYPASS | CANCELED | |||||
BYPASS: This appears when one or more |
| FIRE | NIGHT | NOT READY | ||||
|
|
| FA215KP |
| ||||
| burglary protection zones have been |
|
|
|
| |||
| bypassed. |
| ||||||
NOT READY: | Appears when burglary portion of the system is not ready for arming | |||||||
| (due to open protection zones). The system is ready to arm when this | |||||||
| message disappears and the READY indicator light comes on. |
| ||||||
NO AC: | Appears when AC power has been cut off. System is operating on | |||||||
| backup battery power. |
|
|
|
|
|
| |
AC: | Appears when AC power is present. |
|
|
|
|
|
| |
CHIME: | Appears when the CHIME feature is activated. |
|
|
| ||||
BAT: | Low battery condition in a wireless sensor (if zone number displayed) | |||||||
| or low system battery (if no zone number displayed). |
|
|
| ||||
ALARM: | Appears when an intrusion has been detected and the system is armed | |||||||
| (also appears during a fire alarm or audible emergency alarm). | |||||||
| Accompanied by the protection zone in alarm. |
|
|
| ||||
CHECK: | Appears when a malfunction is discovered in the system at any time or | |||||||
| if an open is detected in a FIRE zone at any time or a fault in a | |||||||
| DAY/NIGHT burglary zone during a disarmed period. Accompanied by | |||||||
| a display of zone number in trouble. |
|
|
|
|
|
| |
FIRE: | Appears when a fire alarm is present. Accompanied by a display of the | |||||||
| zone in alarm. |
|
|
|
|
|
| |
| A FIRE display also appears when a fire alarm is manually activated, | |||||||
| accompanied by a display of emergency key zone number programmed | |||||||
| for fire. |
|
|
|
|
|
| |
NIGHT: | Appears with “STAY” when the system is armed in | |||||||
| (perimeter burglary zones and | |||||||
CANCELED: | Appears when an alarm has been canceled (see Exit Alarm section on | |||||||
| page 13 for more information on canceled alarms and displays). |
– 9 –