Summary of Audible/Visual Notifications
Alpha Display Keypads
SOUND | CAUSE | DISPLAY | |
LOUD, | FIRE ALARM. | FIRE is displayed; descriptor of zone in alarm is | |
INTERRUPTED* |
| displayed. If a fire alarm is manually activated, zone | |
Keypad & Ext. |
| number 95 will be displayed. | |
|
|
| |
LOUD, | BURGLARY/AUDIBLE | ALARM is displayed. If programmed, descriptor of | |
CONTINUOUS* | EMERGENCY ALARM. | zone in alarm is also displayed | |
Keypad & Ext. |
|
| |
|
|
| |
ONE SHORT BEEP | a. SYSTEM DISARM. | a. DISARMED/READY TO ARM is displayed. | |
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. Number and descriptor of open protection zone is | |
Keypad only | |||
WITH AN OPENZONE. | displayed. | ||
| |||
| c. BYPASS VERIFY. | c. Numbers and descriptors of the bypassed zones | |
|
| are displayed (One beep is heard for each | |
|
| zone displayed). Subsequently, the following is | |
|
| displayed: DISARMED BYPASS /Ready to Arm. | |
ONE SHORT BEEP | a. SYSTEM IS IN TEST MODE. | a. Opened Zone identifications will appear. | |
(once every 40 secs) | b, LOW BATTERY AT A | b. LO BAT displayed with description of transmitter. | |
Keypad only | TRANSMITTER. | c. No special display. | |
| c. SYSTEM WILL AUTOARM | ||
|
| ||
| WITHIN 10 MINUTES |
| |
|
|
| |
TWO SHORT BEEPS | ARM AWAY or MAXIMUM. | ARMED AWAY or MAXIMUM displayed. Red | |
Keypad only |
| ARMED indicator lit. | |
THREE SHORT | a. ARM STAY, | a. ARMED STAY or ARMED INSTANT displayed. | |
BEEPS | OR INSTANT. | Red ARMED indicator lit. | |
Keypad only |
| b. CHIME displayed, descriptor of open protection | |
| b. ZONE OPENED WHILE | ||
| zone will be displayed if the [∗] key is pressed. | ||
| SYSTEM IS DISARMED. |
| |
RAPID BEEPING | a. TROUBLE. | a. CHECK displayed. Descriptor of troubled | |
Keypad only | b. MEMORY OF ALARM. | protection zone is displayed. | |
| b. FIRE or ALARM is displayed; descriptor of zone | ||
|
| ||
| c. SYSTEM LOW BATTERY. | in alarm is displayed. | |
| c. SYSTEM LO BAT displayed. | ||
| d. EXT. SOUNDER WIRE FAIL | ||
| d. BELL FAILURE is displayed. | ||
| e. LAST 10 SEC of EXIT DELAY. | ||
| e. No special display. | ||
SLOW BEEPING | a. EXIT DELAY WARNING | a. ARMED AWAY OR MAXIMUM is displayed | |
Keypad only | (if programmed). | along with You May Exit Now. | |
| b. ENTRY DELAY WARNING. | b. DISARM SYSTEM OR ALARM WILL OCCUR | |
|
| is displayed. Exceeding the delay time without | |
|
| disarming causes an alarm. |
*If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.