Testing the System (To Be Conducted Weekly)

About Testing the System

Test mode allows each protection point to be checked for proper operation.

The keypad sounds a single beep about every 30 seconds as a reminder that the system is in the Test mode.

Alarm messages are not sent to your Central Station while Test mode is on.

1Disarm the system and close all protected windows, doors, etc. The READY indicator light should come on if all zones are intact (i.e., all protected windows, doors, etc. are closed.

Alpha Displays:

DISARMED READY TO ARM

2.

 

 

 

 

 

 

 

+

5

then [0] (walk)

(Master Code)

TEST

The Dial test (option “1”) is intended for the installer and should not be used unless directed to do so by your Security System Representative.

3.Listen. The external sounder should sound for about 1 second then turn off. If the sounder does not sound, CALL FOR SERVICE. The “Test in Progress” display appears only on the keypad that started the test.

1 = DIAL, 0 = WALK

TEST IN PROGRESS

4.Fault zones. Open each protected door and window in turn and listen for three beeps from the keypad. Identification (zone number or zone description) of each faulted protection point should appear on the display. The display clears when the door or window is closed.

5.Walk in front of any interior motion detectors (if used) and listen for three beeps. The identification of the detector should appear on the display when it is activated. The display clears when no motion is detected.

Note that if wireless motion detectors are used, there is a 3-minute delay between activations. This is to conserve battery life.

6.Test all smoke detectors, following the manufacturer's instructions. The identification of each detector should appear on the display when each is activated. If a problem is experienced with any protection point (no confirming sounds, no display), call for service immediately.

When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the keypad.

7. Exit test mode:

+[ 1 ]

(Security Code)

If the test mode is inadvertently left active, it automatically turns off after 4 hours. During the final five minutes, the keypad will emit a double beep every 30 seconds.

– 38 –

Image 38
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA About This Manual Table of Contents Panic Keys Macro Key Programming & Usage Using Device Commands Paging FeatureEvent Logging Procedures Security Codes & Authority LevelsSystem Basics System OverviewIntroduction Zones and Partitions AlarmsMemory of Alarm Arming, Step-Arming and Disarming Burglary ProtectionMessage Center Functions Using the Voice Message Center if Voice Keypad is installedPhone Access About The Keypads General InformationFixed-Word Display Keypad Functions of the Keypads Display WindowStay Entry Delay Entry/Exit DelaysExit Delay Exit Alarms Exit Error ConditionsChecking For Open Zones Using the ∗ KeyTo turn the Voice Status feature on/off # Arming the System Quick Arming Arming CommandsModes of Arming Press these keys… Keypad Confirms By… Function Key ArmingKey First Press Second Press Third Press Step Arming FeatureSingle Button Arming To arm in the Away mode Using the KeyswitchUsing the Keyswitch To arm in the Stay modeDisarming and Silencing Alarms Using the OFF keyUsing the Bypass Key Bypassing Protection ZonesQuick Bypass To turn Chime Mode off Chime ModeTo turn Chime Mode on To turn Voice Chime Mode on or offViewing the Current Date and Time Setting the Date and TimeDate and Time Panic Keys Using Panic KeysThis Function Sends this signal With This Sounding… To activate a Panic FunctionMacro Key Programming & Usage About Macro KeysUsing a Programmed Macro Key Example of Macro ProgrammingTo Activate Devices Using Device CommandsAbout Device Commands To Deactivate DevicesPaging Feature About Automatic PagingManual Paging Latch Key PagingAuthority Level Definitions Security Codes & Authority LevelsAbout Security Codes How to Assign Security Codes and Attributes Accessing Other Partitions FA168CPS About Accessing PartitionsMulti-Partition Arming Accessing Other PartitionsUsing the GoTo Command Common Zone Operation Creating Schedules SchedulingAbout Scheduling Group Number Partition Start Smtwtfs Viewing the Event Log Event Logging ProceduresAbout Event Logging Understanding the Type of Event DisplayedTesting the System To Be Conducted Weekly About Testing the SystemCheck and Battery Displays Trouble ConditionsRcvr Jam AlarmFault Or CheckBusy-Standby Long Rng TrblSilencing Low Battery Warning Tones at Keypad Maintaining Your SystemFire Alarm System If Installed This Section Applies only to Residential SystemsIndividual Keys Key PairsKitchen Dining Emergency Evacuation Function Procedure Comments Quick Guide to Basic System FunctionsSummary of Audible/Visual Notifications Fixed-Word Display KeypadsSummary of Audible/Visual Notifications Industry Canada Regulatory Statements and WarningsFederal Communications Commission FCC Part FCC PartRegulatory Statements Industrie CanadaCharts of Your System’s Features Function Keys CommentsCharts of Your System’s Features User User’s Parts Security Auth Access RF Zone Pager No. † Paging Setup List of Output Devices Page Page Page Page OWNER’S Insurance Premium Credit Request Cont Limitations of this System ÊK5309-5V4DŠ