First Alert FA148CPSIA, FA168CPSSIA Zones and Partitions, Alarms, Memory of Alarm, Function Keys

Page 6

System Overview (Continued)

Zones and Partitions

The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.).

Zone numbers are displayed at the keypad when an alarm or trouble condition occurs on a sensor.

Partitions (FA168CPS) provide two independent areas of protection, with each partition containing a group of zones that can be armed and disarmed without affecting other zones or users.

Partitioned systems (FA168CPS) can include a common zone area, which is an area shared by users of both partitions (such as a lobby in a building).

Arming, Step-Arming and Disarming Burglary Protection

The system must be armed before the burglary protection can sense intrusions.

To arm your system, enter your user code followed by the desired arming key.

If programmed, you can press the [#] key in place of your security code when arming the system (e.g., instead of entering your 4-digit security code + [3-STAY] to arm the system in STAY mode, you can press [#] + [3-STAY]).

You can use the step-arming key, if programmed, to arm the system, which lets you arm the system in one of three modes by simply pressing the key repeatedly.

To disarm the system, enter your security code then press the [OFF] key.

Alarms

When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm.

If your system is connected to a Central Monitoring Station, an alarm message is also sent. (Delayed Reporting Note: Message reporting is delayed 30 seconds by default to reduce false alarms. If desired, this delay can be removed or can be increased to 45 seconds. See your installer if you want the delay time changed.)

To stop the alarm sounding, simply disarm the system.

Memory of Alarm

When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (e.g., “FIRE”).

The message remains displayed even after disarming the system, but can be cleared with another “off” sequence.

Function Keys

The “A”, “B”, “C”, and “D” keys on the keypad can be programmed to perform various functions.

Functions include: activate a Panic alarm; arm the system; provide step arming; switch lights on/off; send a message to a pager; display Time/Date; start a Macro.

Scheduling

Your system can be programmed to automatically perform certain functions (e.g., arm the system) at a predetermined time each day.

– 6 –

Image 6
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA About This Manual Table of Contents Panic Keys Macro Key Programming & Usage Using Device Commands Paging FeatureEvent Logging Procedures Security Codes & Authority LevelsSystem Overview IntroductionSystem Basics Zones and Partitions AlarmsMemory of Alarm Arming, Step-Arming and Disarming Burglary ProtectionUsing the Voice Message Center if Voice Keypad is installed Phone AccessMessage Center Functions About The Keypads General InformationFixed-Word Display Keypad Functions of the Keypads Display WindowStay Entry/Exit Delays Exit DelayEntry Delay Exit Alarms Exit Error ConditionsUsing the ∗ Key To turn the Voice Status feature on/off #Checking For Open Zones Arming the System Quick Arming Arming CommandsModes of Arming Press these keys… Keypad Confirms By… Function Key ArmingStep Arming Feature Single Button ArmingKey First Press Second Press Third Press To arm in the Away mode Using the KeyswitchUsing the Keyswitch To arm in the Stay modeDisarming and Silencing Alarms Using the OFF keyUsing the Bypass Key Bypassing Protection ZonesQuick Bypass To turn Chime Mode off Chime ModeTo turn Chime Mode on To turn Voice Chime Mode on or offSetting the Date and Time Date and TimeViewing the Current Date and Time Panic Keys Using Panic KeysThis Function Sends this signal With This Sounding… To activate a Panic FunctionMacro Key Programming & Usage About Macro KeysUsing a Programmed Macro Key Example of Macro ProgrammingTo Activate Devices Using Device CommandsAbout Device Commands To Deactivate DevicesPaging Feature About Automatic PagingManual Paging Latch Key PagingSecurity Codes & Authority Levels About Security CodesAuthority Level Definitions How to Assign Security Codes and Attributes Accessing Other Partitions FA168CPS About Accessing PartitionsAccessing Other Partitions Using the GoTo CommandMulti-Partition Arming Common Zone Operation Scheduling About SchedulingCreating Schedules Group Number Partition Start Smtwtfs Viewing the Event Log Event Logging ProceduresAbout Event Logging Understanding the Type of Event DisplayedTesting the System To Be Conducted Weekly About Testing the SystemCheck and Battery Displays Trouble ConditionsRcvr Jam AlarmFault Or CheckBusy-Standby Long Rng TrblSilencing Low Battery Warning Tones at Keypad Maintaining Your SystemFire Alarm System If Installed This Section Applies only to Residential SystemsIndividual Keys Key PairsKitchen Dining Emergency Evacuation Function Procedure Comments Quick Guide to Basic System FunctionsSummary of Audible/Visual Notifications Fixed-Word Display KeypadsSummary of Audible/Visual Notifications Industry Canada Regulatory Statements and WarningsFederal Communications Commission FCC Part FCC PartRegulatory Statements Industrie CanadaCharts of Your System’s Features Function Keys CommentsCharts of Your System’s Features User User’s Parts Security Auth Access RF Zone Pager No. † Paging Setup List of Output Devices Page Page Page Page OWNER’S Insurance Premium Credit Request Cont Limitations of this System ÊK5309-5V4DŠ