First Alert FA168CPSSIA manual Quick Guide to Basic System Functions, Function Procedure Comments

Page 47

Quick Guide to Basic System Functions

 

 

FUNCTION

PROCEDURE

COMMENTS

 

 

 

 

 

 

 

 

Check Zones

Press READY key.

View faulted zones when system not

 

 

 

 

ready.

 

 

 

 

 

 

 

 

Arm System

Enter code. Press arming key desired:

Arms system in mode selected.

 

 

 

(AWAY, STAY, NIGHT-STAY,

 

 

 

 

 

MAXIMUM, INSTANT)

 

 

 

 

 

 

 

 

 

 

Quick Arm

Press #. Press arming key desired:

Arms system in mode selected, quickly

 

 

(if programmed)

(AWAY, STAY, MAXIMUM, INSTANT)

and without use of a code.

 

 

 

 

 

 

 

 

Bypass Zone(s)

Enter code. Press BYPASS [6] key.

Bypassed zones are unprotected and

 

 

 

Enter zone number(s) to be bypassed

will not cause an alarm if violated.

 

 

 

(use 2-digit entries).

 

 

 

 

 

 

 

 

 

 

Quick Bypass

Enter code. Press BYPASS [6] key + [#].

Bypasses all faulted zones

 

 

(if programmed)

 

automatically.

 

 

 

 

 

 

 

 

Silence Sounders

 

 

 

 

 

Burglary:

Enter code. Press OFF [1] key.

Also disarms system. Memory of alarm

 

 

 

 

remains until cleared.

 

 

Fire:

Press OFF [1] key.

Memory of Alarm remains until cleared.

 

 

"Check":

Press any key.

Determine cause.

 

 

 

 

 

 

 

 

Disarm System

Enter code. Press OFF [1] key. (OFF

Also silences sounders. Memory of

 

 

 

need not be pressed if entry delay or an

alarm remains until cleared.

 

 

 

alarm is active)

 

 

 

 

 

 

 

 

 

 

Clear Alarm

After disarming, enter code again.

Keypad beeps rapidly on entry if alarm

 

 

Memory

Press OFF [1] key again.

has occurred while absent. Alarm

 

 

 

 

display will remain upon disarming

 

 

 

 

until cleared.

 

 

 

 

 

 

 

 

Duress (if active

Arm or disarm "normally", but

Performs desired action and sends

 

 

and connected to

use your 4-digit Duress code to do so.

silent alarm to Central Station.

 

 

Central Station)

 

 

 

 

 

Panic Alarms

Press key [A], [B], or [C] for at least 2

See the Panic Keys section for

 

 

(as programmed)

seconds or press and hold designated key

emergency functions programmed for

 

 

 

pairs: [1]+[∗], or [∗] + [#], or [3] + [#].

your system. Note: Keys “A”, “B”, and

 

 

 

 

“C” may have been programmed for

 

 

 

 

other functions.

 

 

 

 

 

 

 

 

Chime Mode

To turn ON or OFF: Enter code. Press

The keypad will sound if doors or

 

 

 

CHIME key.

windows are violated while system is

 

 

 

 

disarmed and chime mode is ON.

 

 

 

 

 

 

 

 

Test Mode

To turn ON: Enter code. Press TEST key,

Tests alarm sounder and allows sensors

 

 

 

then [0].

to be tested.

 

 

 

To turn OFF: Enter code. Press OFF key.

 

 

 

 

 

 

 

 

 

 

Phone Access

Consult Phone Access User's Guide that

Permits system access remotely, via

 

 

if applicable

accompanies the Phone Module.

Touch-tone phone.

 

 

 

 

 

 

 

 

 

 

 

 

– 47 –

Image 47
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA About This Manual Table of Contents Security Codes & Authority Levels Using Device Commands Paging FeatureEvent Logging Procedures Panic Keys Macro Key Programming & UsageSystem Basics System OverviewIntroduction Arming, Step-Arming and Disarming Burglary Protection AlarmsMemory of Alarm Zones and PartitionsMessage Center Functions Using the Voice Message Center if Voice Keypad is installedPhone Access General Information About The KeypadsFixed-Word Display Keypad Display Window Functions of the KeypadsStay Entry Delay Entry/Exit DelaysExit Delay Exit Error Conditions Exit AlarmsChecking For Open Zones Using the ∗ KeyTo turn the Voice Status feature on/off # Arming the System Function Key Arming Arming CommandsModes of Arming Press these keys… Keypad Confirms By… Quick ArmingKey First Press Second Press Third Press Step Arming FeatureSingle Button Arming To arm in the Stay mode Using the KeyswitchUsing the Keyswitch To arm in the Away modeUsing the OFF key Disarming and Silencing AlarmsBypassing Protection Zones Using the Bypass KeyQuick Bypass To turn Voice Chime Mode on or off Chime ModeTo turn Chime Mode on To turn Chime Mode offViewing the Current Date and Time Setting the Date and TimeDate and Time To activate a Panic Function Using Panic KeysThis Function Sends this signal With This Sounding… Panic KeysAbout Macro Keys Macro Key Programming & UsageExample of Macro Programming Using a Programmed Macro KeyTo Deactivate Devices Using Device CommandsAbout Device Commands To Activate DevicesAbout Automatic Paging Paging FeatureLatch Key Paging Manual PagingAuthority Level Definitions Security Codes & Authority LevelsAbout Security Codes How to Assign Security Codes and Attributes About Accessing Partitions Accessing Other Partitions FA168CPSMulti-Partition Arming Accessing Other PartitionsUsing the GoTo Command Common Zone Operation Creating Schedules SchedulingAbout Scheduling Group Number Partition Start Smtwtfs Understanding the Type of Event Displayed Event Logging ProceduresAbout Event Logging Viewing the Event LogAbout Testing the System Testing the System To Be Conducted WeeklyTrouble Conditions Check and Battery DisplaysOr Check AlarmFault Rcvr JamLong Rng Trbl Busy-StandbyMaintaining Your System Silencing Low Battery Warning Tones at KeypadThis Section Applies only to Residential Systems Fire Alarm System If InstalledKey Pairs Individual KeysKitchen Dining Emergency Evacuation Quick Guide to Basic System Functions Function Procedure CommentsFixed-Word Display Keypads Summary of Audible/Visual NotificationsSummary of Audible/Visual Notifications FCC Part Regulatory Statements and WarningsFederal Communications Commission FCC Part Industry CanadaIndustrie Canada Regulatory StatementsFunction Keys Comments Charts of Your System’s FeaturesCharts of Your System’s Features User User’s Parts Security Auth Access RF Zone Pager No. † Paging Setup List of Output Devices Page Page Page Page OWNER’S Insurance Premium Credit Request Cont Limitations of this System ÊK5309-5V4DŠ