First Alert FA142C user manual ENTRY/EXIT Delays, Seconds

Page 12

Technical Manuals Online! - http://www.tech-man.com

ENTRY/EXIT DELAYS

General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the entry/exit door. The system must be disarmed, however, before the entry delay period ends, or an alarm will occur. The keypad will beep slowly during the entry de- lay period, reminding you to disarm the system.

You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM arming modes. These modes can provide greater security while you are sleeping or while you are away for extended periods of time.

See your installer for your delay times and record them here:

 

Exit Delay:

 

seconds

Entry Delay:

 

seconds

 

 

 

 

Remember, there will be no entry delay

 

 

 

 

when arming INSTANT or MAXIMUM.

Exit Delay

If so programmed by your installer, when arming AWAY (see page 18) or MAXIMUM (see

Alerting Sound

page 19), slow beeps will sound from the keypad during exit delay, turning to fast beeps

 

during the final five seconds of the delay time.

 

 

 

Ask your installer if this is active for your system, and if so, check here:

– 1 2 –

Image 12
Contents Users Manual Table of Contents System Overview Section, about the KeypadsSecurity code + OFF key twice About the Keypads Alarm AwayA Y S T a N TTechnical Manuals Online Functions of the Keypad See Typical Alpha Keypad on NextTech-man.com Security Codes General To Assign, Change, or Delete User CodesDuress Code To Change Your Master Code Duress code may be any 4-digit code assigned to User NumberEnter the Master Code + 8 + 8 + new 4-digit duress code Phone Voice ModuleENTRY/EXIT Delays SecondsChecking for Open Zones To Display Open ZONES, Press KEYUsing Bypass Key Bypassing Protection ZonesTo Bypass Zones Enter Zone NosBypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key Arme D * MAX ImumDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModePanic Keys Press an active lettered key for at least two secondsPress both keys of an active pair at the same time Output Relay Options Programmed ActionsTesting the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsOther Trouble Displays Words or letters in parenthesesSystem LO BAT LO BAT + zone descriptor or BAT with zone NoOpen Circuit Fire Alarm System if Installed OFF key again to clear Memory of AlarmBy fanning the detector for about 30 seconds Pressing the OFF key\X C \ Press \X 3 and \X If the keypad does not have individual lettered keysTechnical Manuals Online Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions N C T I O N O C E D U R E M M E N T SSummary of AUDIBLE/VISUAL Notifications U N D U S E S P L a YFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsOwners Insurance Premium Credit Request Owners Insurance Premium T I C E I SUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.