First Alert FA142C Other Trouble Displays, Words or letters in parentheses, System LO BAT

Page 27

Technical Manuals

TROUBLE CONDITIONS

Online! - http://www.tech

Other Trouble

Displays

*Any “beeping” that accompanies a trouble display can be stopped by entering an OFF sequence (code +

Words or letters in parentheses (

[

1.COMM. FAILURE (or FC)

2.SYSTEM LO BAT

(or BAT with no zone No.)

) are those that are displayed on Fixed-word keypads.

Indicates that a failure has occurred in the telephone com- munication portion of your system.

CALL FOR SERVICE IMMEDIATELY.

Indicates that a low system battery condition exists. This will be accompanied by a once-per-minute "beeping"* at the Keypad. If this condition persists for more than one day (with AC present), CALL FOR SERVICE.

-man.com

OFF)

**Not all systems use wireless transmitters.

3.LO BAT + zone descriptor (or BAT with zone No.)

4.MODEM COMM (or CC)

Indicates that a low battery condition exists in the wireless transmitter** number displayed. This will be accompanied by a once-per-minute "beeping"* at the Keypad. Either replace the battery yourself, or CALL FOR SERVICE. If the battery is not replaced within 30 days, a CHECK display may occur.

Some wireless sensors contain a non-replaceable long-life battery which requires replacement of the entire unit at the end of battery life (e.g., 5802 Pendant and 5802CP Belt Clip Personal Emergency Transmitters).

Indicates that the control is on-line with the central station's remote computer. The control will not operate while on- line. Wait a few minutes. The display should disappear.

2 7

Image 27
Contents Users Manual Table of Contents Section, about the Keypads System OverviewSecurity code + OFF key twice About the Keypads S T a N T AlarmAway A YTechnical Manuals Online See Typical Alpha Keypad on Next Functions of the KeypadTech-man.com Security Codes General To Assign, Change, or Delete User CodesDuress Code Phone Voice Module To Change Your Master CodeDuress code may be any 4-digit code assigned to User Number Enter the Master Code + 8 + 8 + new 4-digit duress codeSeconds ENTRY/EXIT DelaysTo Display Open ZONES, Press KEY Checking for Open ZonesEnter Zone Nos Using Bypass KeyBypassing Protection Zones To Bypass ZonesQuick Bypass Bypassing Protection ZonesArming Perimeter only Using Stay KeyUsing Instant Key With Entry Delay OFFArming ALL Protection Using Away KeyArme D * MAX Imum Using Maximum KeyUsing OFF Key Disarming the System and Silencing AlarmsChime Mode Exit AlarmsPanic Keys Press an active lettered key for at least two secondsPress both keys of an active pair at the same time Programmed Actions Output Relay OptionsUsing Test Key Testing the SystemPaging Feature Testing the SystemTrouble Conditions Check and Battery DisplaysLO BAT + zone descriptor or BAT with zone No Other Trouble DisplaysWords or letters in parentheses System LO BATOpen Circuit Pressing the OFF key Fire Alarm System if InstalledOFF key again to clear Memory of Alarm By fanning the detector for about 30 secondsIf the keypad does not have individual lettered keys \X C \ Press \X 3 and \XTechnical Manuals Online Emergency Evacuation Steps to SafetyN C T I O N O C E D U R E M M E N T S Quick Guide to Alarm System FunctionsU N D U S E S P L a Y Summary of AUDIBLE/VISUAL NotificationsFIXED-WORD Display Keypads Protection Zone Descriptions Protection Zones ListOwners Insurance Premium Credit Request Owners Insurance Premium I S T I C EUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.