First Alert FA142C user manual FIXED-WORD Display Keypads

Page 35

Technical Manuals Online! - http://www.tech-man.com

SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

(FIXED-WORD DISPLAY KEYPADS)

S O U N D

C A U S E

D I S P L A Y

LOUD, INTERRUPTED*

FIRE ALARM

FIRE and ALARM are displayed; protection zone in alarm is displayed.

Keypad & External

 

 

LOUD, CONTINUOUS*

BURGLARY/AUDIBLE

ALARM is displayed; protection zone in alarm is also displayed.

Keypad & External

EMERGENCY ALARM

Also see "Exit Alarm Warning Displays and Sounds" on page 21.

ONE SHORT BEEP

a. SYSTEM DISARM

a. Only READY is displayed. Green READY indicator (if present) is lit.

(not repeated)

b. SYSTEM ARMING ATTEMPT

b. NOT READY is displayed, open protection zone number is displayed.

Keypad only

WITH AN OPEN ZONE

Green READY indicator (if present) is not lit.

 

 

c. BYPASS VERIFY

c. The bypassed protection zone numbers are displayed. (One beep for each number

 

 

displayed.) BYPASS displayed.

ONE SHORT BEEP

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

(once every 40 seconds)

 

 

Keypad only

 

 

ONE BEEP every 40 sec.

a. LOW BATTERY AT XMTR

a. BAT displayed with ID number of transmitter.

Keypad only

b. SYST. MAIN BATT. WEAK

b. BAT displayed with no transmitter ID

 

c. TROUBLE

c. CHECK displayed. Troubled protection zone is displayed.

TWO SHORT BEEPS

ARM AWAY OR MAXIMUM

AWAY and (if MAXIMUM) INSTANT are displayed.

Keypad only

 

 

THREE SHORT BEEPS

a. ARM STAY OR INSTANT

a. STAY and (if INSTANT) INSTANT are displayed. Red ARMED indicator is lit.

Keypad only

b. ZONE OPENED WHILE SYS-

b. CHIME displayed. Pressing / READY key will display opened zone.

 

TEM IS IN CHIME MODE

c. Open protection zone number is displayed.

 

c. ZONE OPENED WHILE SYS-

 

TEM IS IN TEST MODE

 

RAPID BEEPING

MEMORY OF ALARM

FIRE and/or ALARM is displayed; zone in alarm is displayed.

Keypad only

 

 

SLOW BEEPING

a. ENTRY DELAY WARNING

a. No display during delay; Exceeding the delay time without disarming causes alarm.

Keypad only

b. EXIT DELAY ALERT

b. AWAY or (if MAXIMUM) AWAY INSTANT is displayed. Slow beeps change to fast during

 

 

(if programmed)

last 5 sec of exit delay.

*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring. Note: Also see Other Trouble Displays and Total Power Failure under TROUBLE CONDITIONS on pages 27 and 28.

– 3 5 –

Image 35
Contents Users Manual Table of Contents Section, about the Keypads System OverviewSecurity code + OFF key twice About the Keypads S T a N T AlarmAway A YTechnical Manuals Online See Typical Alpha Keypad on Next Functions of the KeypadTech-man.com Duress Code Security CodesGeneral To Assign, Change, or Delete User Codes Phone Voice Module To Change Your Master CodeDuress code may be any 4-digit code assigned to User Number Enter the Master Code + 8 + 8 + new 4-digit duress codeSeconds ENTRY/EXIT DelaysTo Display Open ZONES, Press KEY Checking for Open ZonesEnter Zone Nos Using Bypass KeyBypassing Protection Zones To Bypass ZonesQuick Bypass Bypassing Protection ZonesArming Perimeter only Using Stay KeyUsing Instant Key With Entry Delay OFFArming ALL Protection Using Away KeyArme D * MAX Imum Using Maximum KeyUsing OFF Key Disarming the System and Silencing AlarmsChime Mode Exit AlarmsPress both keys of an active pair at the same time Panic KeysPress an active lettered key for at least two seconds Programmed Actions Output Relay OptionsUsing Test Key Testing the SystemPaging Feature Testing the SystemTrouble Conditions Check and Battery DisplaysLO BAT + zone descriptor or BAT with zone No Other Trouble DisplaysWords or letters in parentheses System LO BATOpen Circuit Pressing the OFF key Fire Alarm System if InstalledOFF key again to clear Memory of Alarm By fanning the detector for about 30 secondsIf the keypad does not have individual lettered keys \X C \ Press \X 3 and \XTechnical Manuals Online Emergency Evacuation Steps to SafetyN C T I O N O C E D U R E M M E N T S Quick Guide to Alarm System FunctionsU N D U S E S P L a Y Summary of AUDIBLE/VISUAL NotificationsFIXED-WORD Display Keypads Protection Zone Descriptions Protection Zones ListOwners Insurance Premium Credit Request Owners Insurance Premium I S T I C EUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.