First Alert FA142C user manual Panic Keys, Press an active lettered key for at least two seconds

Page 22

Technical Manuals Online! - http://www.tech-man.com

PANIC KEYS

(FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)

Using

Your system may have been programmed to use special keys or combinations of keys to

Panic Keys

manually activate emergency (panic) functions. The functions that might be programmed

 

are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire.

 

A silent emergency sends a silent alarm signal to the central station*, but there is no

 

audible alarm or visual display.

 

An audible emergency sends a signal to the central station* and sounds a loud,

 

steady alarm at your keypad(s) and at any external sounders that may be connected

 

(ALARM plus a zone number is also displayed).

 

A personal emergency alarm sends an emergency message to the central station*

 

and sounds at keypad(s), but not at external bells or sirens.

 

A fire alarm sends a fire alarm message to the central station* and uniquely sounds at

 

keypad(s) and external bells and sirens (FIRE plus a zone number is also displayed).

 

* If connected to central station.

 

TO INITIATE A PANIC FUNCTION AT ANY TIME OF DAY OR NIGHT:

 

Press an active lettered key for at least two seconds.

 

or

 

Press both keys of an active pair at the same time.

 

 

 

 

 

 

Also see Duress Code feature on page 10.

 

 

 

 

 

– 2 2 –

Image 22
Contents Users Manual Table of Contents System Overview Section, about the KeypadsSecurity code + OFF key twice About the Keypads A Y AlarmAway S T a N TTechnical Manuals Online Functions of the Keypad See Typical Alpha Keypad on NextTech-man.com General To Assign, Change, or Delete User Codes Security CodesDuress Code Enter the Master Code + 8 + 8 + new 4-digit duress code To Change Your Master CodeDuress code may be any 4-digit code assigned to User Number Phone Voice ModuleENTRY/EXIT Delays SecondsChecking for Open Zones To Display Open ZONES, Press KEYTo Bypass Zones Using Bypass KeyBypassing Protection Zones Enter Zone NosBypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key Arme D * MAX ImumDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModePress an active lettered key for at least two seconds Panic KeysPress both keys of an active pair at the same time Output Relay Options Programmed ActionsTesting the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsSystem LO BAT Other Trouble DisplaysWords or letters in parentheses LO BAT + zone descriptor or BAT with zone NoOpen Circuit By fanning the detector for about 30 seconds Fire Alarm System if InstalledOFF key again to clear Memory of Alarm Pressing the OFF key\X C \ Press \X 3 and \X If the keypad does not have individual lettered keysTechnical Manuals Online Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions N C T I O N O C E D U R E M M E N T SSummary of AUDIBLE/VISUAL Notifications U N D U S E S P L a YFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsOwners Insurance Premium Credit Request Owners Insurance Premium T I C E I SUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.