First Alert FA142C user manual Disarming the System and Silencing Alarms, Using OFF Key

Page 20

Technical Manuals

DISARMING THE SYSTEM AND SILENCING ALARMS

Online! - http://www.tech-man.com

Using the

1 OFF Key

I M P O R T A N T :

If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location.

If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon your entering, indicating that an alarm has occurred during your absence.

LEAVE IMMEDIATELY, and CONTACT THE POLICE from a nearby safe location.

The OFF key is used to disarm the system and to silence alarm and trouble sounds.

To Disarm the System

Enter your security code and press the OFF key.

The "Ready" message will be displayed, and the keypad will emit a single tone to confirm that the system is disarmed.

To Silence a Burglary Alarm

SEE IMPORTANT NOTE AT LEFT!

Enter your security code and press the OFF key to silence the alarm (or warning tones of a Memory of Alarm).

Note the zone in alarm on the keypad display, and make that zone intact (close door, window, etc.). Now enter the security code plus OFF sequence again to clear the keypad's Memory of Alarm display. If the display will not clear and does not provide a "Ready" message, notify the alarm agency.

To Silence a Fire Alarm

Simply press the OFF key (the security code is not needed to silence FIRE alarms).

To then clear the keypad's Memory of Alarm display, enter your security code and press the OFF key again. See page 29 for additional fire alarm information.

A FIRE alarm is an interrupted/pulsed sound. A BURGLARY alarm is a continuous/steady sound.

 

TYPICAL FIRE ALARM DISPLAY

 

 

 

 

 

 

 

Ê05

AC

 

 

FIRE 05

 

 

 

 

 

 

 

 

 

 

MASTER BEDROOM

 

 

 

ALARM

 

 

 

 

 

 

F I R E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALPHA

 

 

FIXED-WORD

 

 

TYPICAL BURGLARY ALARM DISPLAY

 

 

 

 

 

 

 

 

 

ALARM 06

 

 

 

06

AC

 

 

 

 

 

 

 

 

MASTER BEDROOM

 

 

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALPHA

 

 

FIXED-WORD

 

 

– 2 0 –

Image 20
Contents Users Manual Table of Contents System Overview Section, about the KeypadsSecurity code + OFF key twice About the Keypads Alarm AwayA Y S T a N TTechnical Manuals Online Functions of the Keypad See Typical Alpha Keypad on NextTech-man.com Duress Code Security CodesGeneral To Assign, Change, or Delete User Codes To Change Your Master Code Duress code may be any 4-digit code assigned to User NumberEnter the Master Code + 8 + 8 + new 4-digit duress code Phone Voice ModuleENTRY/EXIT Delays SecondsChecking for Open Zones To Display Open ZONES, Press KEYUsing Bypass Key Bypassing Protection ZonesTo Bypass Zones Enter Zone NosBypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key Arme D * MAX ImumDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModePress both keys of an active pair at the same time Panic KeysPress an active lettered key for at least two seconds Output Relay Options Programmed ActionsTesting the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsOther Trouble Displays Words or letters in parenthesesSystem LO BAT LO BAT + zone descriptor or BAT with zone NoOpen Circuit Fire Alarm System if Installed OFF key again to clear Memory of AlarmBy fanning the detector for about 30 seconds Pressing the OFF key\X C \ Press \X 3 and \X If the keypad does not have individual lettered keysTechnical Manuals Online Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions N C T I O N O C E D U R E M M E N T SSummary of AUDIBLE/VISUAL Notifications U N D U S E S P L a YFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsOwners Insurance Premium Credit Request Owners Insurance Premium T I C E I SUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.