First Alert FA142C user manual Functions of the Keypad, See Typical Alpha Keypad on Next

Page 8

Technical Manuals

FUNCTIONS OF THE KEYPAD

SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE

Online! - http://www.tech-man.com

1.DISPLAY WINDOW. Alpha Keypad: A 2-line, 32- character Liquid Crystal Display (LCD). Displays protection zone identification, system status, and messages (see page 9).

Fixed-Word Keypad: Displays protection zone ID and system status messages using pre-designated words (see page 6).

2.OFF KEY: Disarms burglary portion of the system, silences alarms and audible trouble indicators, and clears visual display after problem's correction.

3.AWAY KEY: Arms the entire burglary system, perimeter and interior.

4.STAY KEY: Arms perimeter portion of burglary system only. Interior protection is not armed, which allows movement within premises without causing alarm.

5.MAXIMUM KEY: Arms in manner similar to AWAY mode, but without the entry delay feature, thus providing maximum protection. An alarm will occur immediately upon opening any protection point, including the main door.

6.TEST KEY: Tests the system and alarm sounder if disarmed. Refer to TESTING THE SYSTEM section for test procedures.

7.BYPASS KEY: Removes individual protection zones from being monitored by the system.

8.INSTANT KEY: Arms in manner similar to STAY mode, but without the entry delay feature. Entering via the entry/exit door will cause an instant alarm.

9.CODE KEY: Used to assign additional user codes for other users of the system.

10.CHIME KEY: Turns CHIME mode on and off. When on, the opening of windows or doors while the system is disarmed will sound 3 beeps at the keypad(s).

11. READY KEY: Displays all open protection zones.

12.# KEY: "Quick Arm" key permits ARMING of the sys- tem without the use of a security code (if so programmed).

13.KEYS 0–9:Used to enter your security code(s). See Note at top of next page.

14.READY INDICATOR: (GREEN) Lit when the system is ready to be armed (no faults present). While the system is disarmed, this indicator will go on and off as protection zones are closed and opened.

15.ARMED INDICATOR: (RED) Lit when the system has been armed (STAY, AWAY, INSTANT or MAXIMUM).

16.INTERNAL SOUNDER: The built-in keypad sounder mimics the alarm sounder during alarms, and will also "beep" during certain system functions (see SUMMARY OF AUDIBLE/ VISUAL NOTIFICATION).

17.EMERGENCY (PANIC) KEYS: Individual keys A, B, and C (key D not used).

On some keypads, these keys are not present and certain key pairs may be available for emergency functions.

For further information, refer to the PANIC KEYS section.

– 8 –

Image 8
Contents Users Manual Table of Contents System Overview Section, about the KeypadsSecurity code + OFF key twice About the Keypads Alarm AwayA Y S T a N TTechnical Manuals Online Functions of the Keypad See Typical Alpha Keypad on NextTech-man.com Duress Code Security CodesGeneral To Assign, Change, or Delete User Codes To Change Your Master Code Duress code may be any 4-digit code assigned to User NumberEnter the Master Code + 8 + 8 + new 4-digit duress code Phone Voice ModuleENTRY/EXIT Delays SecondsChecking for Open Zones To Display Open ZONES, Press KEYUsing Bypass Key Bypassing Protection ZonesTo Bypass Zones Enter Zone NosBypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key Arme D * MAX ImumDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModePress both keys of an active pair at the same time Panic KeysPress an active lettered key for at least two seconds Output Relay Options Programmed ActionsTesting the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsOther Trouble Displays Words or letters in parenthesesSystem LO BAT LO BAT + zone descriptor or BAT with zone NoOpen Circuit Fire Alarm System if Installed OFF key again to clear Memory of AlarmBy fanning the detector for about 30 seconds Pressing the OFF key\X C \ Press \X 3 and \X If the keypad does not have individual lettered keysTechnical Manuals Online Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions N C T I O N O C E D U R E M M E N T SSummary of AUDIBLE/VISUAL Notifications U N D U S E S P L a YFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsOwners Insurance Premium Credit Request Owners Insurance Premium T I C E I SUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.