TESTING THE SYSTEM (Continued)

7.After all protection points have been checked and restored, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY.

8.Turn off the Test mode by entering the security code and pressing the OFF key.

PAGING FEATURE

If the paging feature has been programmed for your system, your pager will respond to certain conditions as they occur in your system by displaying a 10-digit code that will indicate the type of condition that has occurred. The 10-digit code will use the following format: SSSS–EEE–NNN

SSSSwill be your particular 4-digit subscriber No. (this same number will always appear at the beginning of the display on your pager).

EEE will be a 3-digit number that describes the event that has occurred in your system (see explanation below). NNN will be a 3-digit User or zone number, depending on the type of event that has occurred.

The 3-digit Event Codes (EEE) that can be displayed are:

911 = Alarm (NNN that follows this code will be the zone number that has caused the alarm)

001 = Open, System disarmed (NNN that follows this code will be the User number)

002 = Close, System armed (NNN that follows this code will be the User number)

811 = Trouble (NNN that follows this code will be the zone number that has caused the trouble)

Example 1. Pager displays: 1 23 4 9 110 0 4 Ê

This indicates that your system (Subscriber No. 1234) is reporting an Alarm (911), due to zone 4 (004) being faulted.

Example 2. Pager displays: 123 4 0 0 10 0 5Ê

This indicates that your system (Subscriber No. 1234) is reporting an open/disarming (001) by User 5 (005).

– 2 5 –

Image 25
Contents Users Manual Table of Contents Section, about the Keypads System OverviewSecurity code + OFF key twice About the Keypads Away AlarmA Y S T a N TTechnical Manuals Online See Typical Alpha Keypad on Next Functions of the KeypadTech-man.com General To Assign, Change, or Delete User Codes Security CodesDuress Code Duress code may be any 4-digit code assigned to User Number To Change Your Master CodeEnter the Master Code + 8 + 8 + new 4-digit duress code Phone Voice ModuleSeconds ENTRY/EXIT DelaysTo Display Open ZONES, Press KEY Checking for Open ZonesBypassing Protection Zones Using Bypass KeyTo Bypass Zones Enter Zone NosQuick Bypass Bypassing Protection ZonesArming Perimeter only Using Stay KeyUsing Instant Key With Entry Delay OFFArming ALL Protection Using Away KeyArme D * MAX Imum Using Maximum KeyUsing OFF Key Disarming the System and Silencing AlarmsChime Mode Exit AlarmsPress an active lettered key for at least two seconds Panic KeysPress both keys of an active pair at the same time Programmed Actions Output Relay OptionsUsing Test Key Testing the SystemPaging Feature Testing the SystemTrouble Conditions Check and Battery DisplaysWords or letters in parentheses Other Trouble DisplaysSystem LO BAT LO BAT + zone descriptor or BAT with zone NoOpen Circuit OFF key again to clear Memory of Alarm Fire Alarm System if InstalledBy fanning the detector for about 30 seconds Pressing the OFF keyIf the keypad does not have individual lettered keys \X C \ Press \X 3 and \XTechnical Manuals Online Emergency Evacuation Steps to SafetyN C T I O N O C E D U R E M M E N T S Quick Guide to Alarm System FunctionsU N D U S E S P L a Y Summary of AUDIBLE/VISUAL NotificationsFIXED-WORD Display Keypads Protection Zone Descriptions Protection Zones ListOwners Insurance Premium Credit Request Owners Insurance Premium I S T I C EUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.