First Alert FA142C user manual Federal Communications Commission FCC Part 68 Statement

Page 41

Technical Manuals Online! - http://www.tech-man.com

FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT

This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.

This equipment uses the following jacks:

An RJ31X is used to connect this equipment to the telephone network.

The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary dis- continuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.

If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved.

There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product.

This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs.

This equipment is hearing-aid compatible.

When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early morning or late evening.

– 4 1 –

Image 41
Contents Users Manual Table of Contents Section, about the Keypads System OverviewSecurity code + OFF key twice About the Keypads Away AlarmA Y S T a N TTechnical Manuals Online See Typical Alpha Keypad on Next Functions of the KeypadTech-man.com Duress Code Security CodesGeneral To Assign, Change, or Delete User Codes Duress code may be any 4-digit code assigned to User Number To Change Your Master CodeEnter the Master Code + 8 + 8 + new 4-digit duress code Phone Voice ModuleSeconds ENTRY/EXIT DelaysTo Display Open ZONES, Press KEY Checking for Open ZonesBypassing Protection Zones Using Bypass KeyTo Bypass Zones Enter Zone NosQuick Bypass Bypassing Protection ZonesArming Perimeter only Using Stay KeyUsing Instant Key With Entry Delay OFFArming ALL Protection Using Away KeyArme D * MAX Imum Using Maximum KeyUsing OFF Key Disarming the System and Silencing AlarmsChime Mode Exit AlarmsPress both keys of an active pair at the same time Panic KeysPress an active lettered key for at least two seconds Programmed Actions Output Relay OptionsUsing Test Key Testing the SystemPaging Feature Testing the SystemTrouble Conditions Check and Battery DisplaysWords or letters in parentheses Other Trouble DisplaysSystem LO BAT LO BAT + zone descriptor or BAT with zone NoOpen Circuit OFF key again to clear Memory of Alarm Fire Alarm System if InstalledBy fanning the detector for about 30 seconds Pressing the OFF keyIf the keypad does not have individual lettered keys \X C \ Press \X 3 and \XTechnical Manuals Online Emergency Evacuation Steps to SafetyN C T I O N O C E D U R E M M E N T S Quick Guide to Alarm System FunctionsU N D U S E S P L a Y Summary of AUDIBLE/VISUAL NotificationsFIXED-WORD Display Keypads Protection Zone Descriptions Protection Zones ListOwners Insurance Premium Credit Request Owners Insurance Premium I S T I C EUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.