First Alert FA142C user manual Table of Contents

Page 2

Technical Manuals

TABLE OF CONTENTS

Online! - http://www.tech-man.com

SYSTEM OVERVIEW

3

General

3

Keypads

3

Zones

3

Burglary Protection

4

Fire Protection

4

Alarms

4

Memory of Alarm

4

Phone Access & Voice Response Capability

4

Paging Feature

4

ABOUT THE KEYPADS

5

General

5

Keypad Displays

5

Fixed-Word Keypad Displays

6

FUNCTIONS OF THE KEYPAD

8

SECURITY CODES

10

General

10

To Assign, Change, or Delete User Codes

10

Duress Code

10

To Change Your Master Code

11

Quick Arming

11

Phone (Voice) Module

11

ENTRY/EXIT DELAYS

12

General

12

Audible Exit Delay Sound

12

CHECKING FOR OPEN ZONES

13

BYPASSING ZONES

14

Using the [BYPASS] Key

14

Quick Bypass

15

ARMING PERIMETER ONLY (STAY)

16

ARMING PERIMETER ONLY (INSTANT)

17

ARMING ALL PROTECTION (AWAY)

18

ARMING ALL PROTECTION (MAXIMUM)

19

DISARMING, AND SILENCING ALARMS

20

EXIT ALARMS

21

CHIME MODE

21

PANIC KEYS

22

OUTPUT RELAY OPTIONS

23

TESTING THE SYSTEM

24

PAGING FEATURE

25

TROUBLE CONDITIONS

26

"CHECK" and "BATTERY" Displays

26

Total Power Failure

26

Other Displays

27

FIRE ALARM SYSTEM (IF INSTALLED)

29

General

29

In Case of Fire Alarm

29

Silencing Fire Alarms

30

Manually Initiating a Fire Alarm

30

NFPA RECOMMENDATIONS

31

EMERGENCY EVACUATION

32

QUICK GUIDE TO SYSTEM FUNCTIONS

33

SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

34

PROTECTION ZONES LIST

36

INSURANCE CREDIT REQUEST FORM

37

CANADIAN (DOC) STATEMENT

39

FCC STATEMENTS

40

LIMITATIONS STATEMENT

42

SERVICING INFORMATION

43

WARRANTY

Back Cover

This manual is a step-by-step guide that will aquaint you with the system's features and benefits. It defines the components and their functions, describes their operation, and instructs you with normal and emergency procedures.

Keep this manual in a convenient place so that you can refer to it as necessary.

– 2 –

Image 2
Contents Users Manual Table of Contents System Overview Section, about the KeypadsSecurity code + OFF key twice About the Keypads A Y AlarmAway S T a N TTechnical Manuals Online Functions of the Keypad See Typical Alpha Keypad on NextTech-man.com Duress Code Security CodesGeneral To Assign, Change, or Delete User Codes Enter the Master Code + 8 + 8 + new 4-digit duress code To Change Your Master CodeDuress code may be any 4-digit code assigned to User Number Phone Voice ModuleENTRY/EXIT Delays SecondsChecking for Open Zones To Display Open ZONES, Press KEYTo Bypass Zones Using Bypass KeyBypassing Protection Zones Enter Zone NosBypassing Protection Zones Quick BypassUsing Stay Key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key Arme D * MAX ImumDisarming the System and Silencing Alarms Using OFF KeyExit Alarms Chime ModePress both keys of an active pair at the same time Panic KeysPress an active lettered key for at least two seconds Output Relay Options Programmed ActionsTesting the System Using Test KeyTesting the System Paging FeatureCheck and Battery Displays Trouble ConditionsSystem LO BAT Other Trouble DisplaysWords or letters in parentheses LO BAT + zone descriptor or BAT with zone NoOpen Circuit By fanning the detector for about 30 seconds Fire Alarm System if InstalledOFF key again to clear Memory of Alarm Pressing the OFF key\X C \ Press \X 3 and \X If the keypad does not have individual lettered keysTechnical Manuals Online Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions N C T I O N O C E D U R E M M E N T SSummary of AUDIBLE/VISUAL Notifications U N D U S E S P L a YFIXED-WORD Display Keypads Protection Zones List Protection Zone DescriptionsOwners Insurance Premium Credit Request Owners Insurance Premium T I C E I SUL Notice This is a Grade a Residential System Federal Communications Commission FCC Part 68 Statement Page Servicing Information ONE Year Limited Warranty

FA142C specifications

The First Alert FA142C is a reliable and efficient combination smoke and carbon monoxide alarm that provides crucial safety features for any home. This innovative device is designed to keep you and your loved ones safe by detecting both smoke and harmful carbon monoxide gas, which is odorless and colorless. With its advanced technology and user-friendly design, the FA142C is an excellent choice for ensuring peace of mind.

One of the standout features of the First Alert FA142C is its dual-sensor technology. It incorporates both photoelectric and ionization sensing capabilities, which enables the device to detect a wide range of smoke types. Photoelectric sensors are more effective at identifying smoldering fires, while ionization sensors are better suited for fast-flaming fires. This combination allows for a quicker response time, giving you the earliest possible warning in case of a fire.

Additionally, the FA142C is equipped with an electrochemical CO sensor that specifically detects carbon monoxide levels in the air. This feature is vital, as carbon monoxide is a silent killer, often referred to as the "invisible threat." The alarm emits a loud warning signal when it detects elevated levels of CO, ensuring that you can take immediate action to protect your family.

The First Alert FA142C also boasts a user-friendly design. The device is battery-operated, requiring no hard wiring, which allows for easy installation in various locations throughout your home. Its low battery chirp alerts you when it's time to replace the batteries, ensuring consistent functionality. Furthermore, the test/silence button enables you to easily check the alarm’s operation and silence nuisance alarms.

In terms of design, this alarm features a sleek, modern look that can blend seamlessly into any décor. The First Alert FA142C also comes with a five-year limited warranty, highlighting the manufacturer’s confidence in the product’s durability and effectiveness.

Overall, the First Alert FA142C is a standout choice for those looking to enhance their home safety. With its dual-sensor technology, reliable carbon monoxide detection, and user-friendly features, this alarm plays a critical role in safeguarding your household against the dangers of fire and CO poisoning. Investing in the FA142C means prioritizing the safety of your home and family.