DMP Electronics XR500 manual Entering Alpha Characters, Entering Non-Alpha Characters

Page 13

Introduction

1.10Entering Alpha Characters

Some options during programming require you to enter alpha characters. To enter an alpha character, press or touch the key that has that letter written below it. The keypad displays the number digit of the key. Next, press the Select key/area that corresponds to the loca­tion of the letter under the key. Pressing a different Select key/area changes the letter. When an­other digit key is pressed, the last letter displayed is retained and the process starts over.

A

B

C

(

First Letter Second Letter

Third Letter

Special Character

A

B

C

(

First Letter

 

Third Letter

 

Second Letter

Special Character

Figure 5: Security Command Select Keys

Figure 6: Thinline/Aqualite Select Keys

1.11Entering Non-Alpha Characters

To enter a space in an alpha entry, press the 9 digit key followed by the third Select key/area. The three characters on the 9 digit key are Y, Z, and space. You can also enter the following characters: – (dash),

. (period), * (asterisk), and # (pound sign) using the 0 (zero) key and the four Select keys/areas from left to right. For example, to enter a – (dash), press the 0 (zero) key and then the left Select key/area. A dash now appears in the keypad display. Figures 7 and 8 show the character location for

Security Command, Thinline, and Aqualite keypads.

1

 

C

B

A

 

5

 

 

O

 

N

 

M

 

9

 

)

 

ace

 

 

(sp

 

Z

 

Y

 

2

 

F

E

D

 

6

 

R

q

P

 

0

 

 

#

 

 

 

 

 

*

 

.

 

 

-

 

 

3

 

I

H

G

 

7

 

U

T

S

 

 

 

4

 

L

K

J

 

8

 

X

W

V

 

CMD

Figure 7: Security Command

Figure 8: Thinline/Aqualite

Special Characters

Special Characters

1.12Keypad Displays Current Programming

Each programming prompt displayed at the keypad shows the currently selected option in the panel memory. These options are either shown as a number, a blank, or a NO or YES. To change a number or blank to a new number, press any top row Select key or touch any Select Area. The current option is replaced with a dash. Press the number(s) on the keypad you want to enter as the new number for that prompt. It is not necessary to enter numbers with leading zeros. The panel automatically right justifies the number when you press the COMMAND key.

To change a programming prompt that requires a NO or YES response, press the Select key or touch the Select Area for the response not selected. See Figure 12.

For example, if the current prompt is selected as YES and you want to change it to NO, on Security Command, Thinline, or Aqualite keypads press the third top row Select key. The display changes to NO. Press the COMMAND key to display the next prompt.

Security

Command

Keypads

Thinline

Aqualite

Keypads

Press the black colored top row Select key/area.

BELL TST

YES

BELL TST

YES

THEN

The keypad displays the new

selection. Press CMD to advance.

 

 

 

 

 

 

BELL TST

NO

 

 

 

 

 

 

BELL TST

NO

 

 

 

 

Figure 9: Changing the Current Programming Option

Digital Monitoring Products

XR500 Series Canadian Programming Guide

4

Image 13
Contents Programming Guide Industry Canada Notice Table Of Contents Messaging Setup Bell Options System ReportsOutput Groups Area Information Zone InformationStop Feature UpgradeThis page intentionally left blank Before you Begin IntroductionGetting Started Encrypted Communications XR500N/XR500E only Reset TimeoutProgrammer Operation Programmer Lockout CodesKeypads Power UpSpecial Keys Entering Non-Alpha Characters Entering Alpha CharactersKeypad Displays Current Programming Special CharactersAsterisks in Programming Multiple DisplaysDevices Areas Initialization Clear Communication and Remote Options Set to Factory DefaultsCommunication Test Report Path TypeTest Frequency Test DayFirst Telephone Number Receiver PortSecond Telephone Number Advanced ProgrammingAlarm Switch Setup StringDuplicate Alarms Retry SecondsDoor Access Report Alarm ReportsSupervisory/Trouble Reports Opening/Closing and User ReportsGateway Address Local IP AddressSubnet Mask DNS ServerMessaging Setup Destination 3 User Number Smtp PasswordEmail Communication Type Smtp ServerDevice Setup User Action Allowed Display AreasStatus Display Allowed Options and Actions Not AffectedStrike Time Strike DelayFire Exit Release Output Group15.1 15.2 Relock on Zone 2 Fault?Program 734 Options Activate Zone 2 ShuntActivate Onboard Speaker 15.6 15.7 15.8Card Options Custom Card DefinitionsRequire Site Code 15.915.9 15.10 Site Code DisplayRemote Options PC Modem Manufacturer AuthorizationAllow Network Remote Network Programming PortEntré Backup TCP Port Entré Backup IP AddressEntré Checkin Entré PassphraseSystem Reports Panic Test Communication XR500N/XR500E only AmbushSystem Options Entry DelaySystem Instant ArmingCross Zone Time Reset Swinger BypassSwgrbyps Trips 1 Swinger Bypass Trips Time Zone ChangesProgramming Menu Language Latch Supervisory ZonesUser Menu and Status List Language City/Time ZoneBypass Limit Detect Wireless JammingCard Plus PIN XR500E only House CodeEnable Keypad Panic Keys Wireless Audible AnnunciationOccupied Premises Enhanced Zone TestBell Options Output Options Sensor Reset Output Panic Alarm Output11.6 11.7 11.811.15 Arm-Alarm OutputClosing Wait Output 11.16Output Information Output Groups Menu Display Status List Burglary Zones 15.5 15.6Supervisory Zones Panic ZonesPrinter Reports PC Log Reports 17.10 Door Acs no YES Door Access Reports17.11 17.12 PC Log Real-Time StatusArea Information Closing Check 18.5 18.6 18.7 18.8 18.9 18.10Closing Code Any BypassHome/Sleep/Away Programming 18.10.2Area Name Automatic ArmingArmed Output Number Late Arm DelayLate Output Number Bank Safe & Vault XR500N/XR500E only19.1 Zone InformationZone Number Zone Name19.5 Zone Type SpecificationsArea Assignment 19.6Arming Zone Area Assignment 19.7 19.8Style Arming Zone OperationWireless DMP Wireless19.9 Next Zone19.10.3 19.10.4 19.10.5 19.10.6 19.10.7 19.10.8 Disarm/DisableLED Operation PIR Pulse Count19.11.1 19.11.2 19.11.3 Series Key FobsKey Fob User Number Key Fob Serial NumberButton Action 19.11.719.11.8 Button Press TimeOutput Action 19.11.10 19.11.11 19.11.12Alarm Action FA Series Wireless 19.1219.12.1 19.12.2 19.12.3 Check-in TimeReport to Transmit 19.15 19.16 19.17Presignal Keypad Addresses Zone Retard Delay19.23 19.24Priority 19.2519.26 Fire Panel Slave InputSet Lockout Code Stop21.1 Set Lockout CodeFeature Upgrade Diagnostics function False Alarm ReductionAppendix Network Results Successful Display Failure Display Cellular Results Successful Display Failure DisplayEmail Results Successful Display Failure Display Successful Display Failure DisplayKeypad Displays Using the 984 Command FunctionWalk Test Using the Walk TestZone Types Trip Counter For Walk TestTest End Warning Trip Counter For DMP Wireless Check-in Test WLSFailed Zones Display Keypad Speaker OperationCross Zoning Report Type Immediately Delayed23.7 Events Manager 23.8 User ProfilesCross Talk FA Series Transmitter InformationZone Type Specifications Wireless Check-in and Supervision DefinitionsKeypad Bus and LX-Bus Zone Type Descriptions Keypad Bus Zone Information Keypad Bus Zone Type DefaultsZone Type Defaults LX-Bus Zone Type DefaultsCommon Keypad Messages Message Meaning Possible SolutionsArea Account Number Messages Revisions to This Document Listings and Approvals Intrusion Fire Access Networks

XR500 specifications

DMP Electronics has made significant waves in the tech industry with its innovative XR500 device, a cutting-edge solution that caters to both professional and consumer needs. The XR500 combines advanced technologies with a user-friendly design to deliver an exceptional user experience.

One of the standout features of the XR500 is its powerful processing capabilities. Equipped with a high-performance processor, the device ensures seamless multitasking and quick access to applications. This allows users to handle demanding tasks such as gaming, content creation, and data analysis without experiencing lag or slowdown.

In terms of display, the XR500 boasts a stunning high-resolution screen that enhances visual clarity and color accuracy. Whether you are watching videos, playing immersive games, or editing images, the vibrant colors and sharp details make every experience enjoyable. The device also supports high refresh rates, providing fluid motion essential for fast-paced gaming.

Another critical characteristic of the XR500 is its versatility. It features multiple connectivity options including USB-C, HDMI, and Bluetooth, enabling users to connect a wide range of peripherals and accessories. This flexibility makes the XR500 suitable for various applications, whether you're in a creative professional environment or simply enjoying media at home.

DMP has also focused on the XR500's audio quality. Equipped with advanced sound technologies, the device delivers an immersive audio experience. Clear and rich sound enhances gaming and movie-watching experiences, ensuring that every detail is heard. The integrated speakers are supplemented by options for external sound systems, catering to audiophiles and casual listeners alike.

Battery life is a crucial consideration for any electronic device, and the XR500 does not disappoint. It features a robust battery that supports extended usage times, making it ideal for users who are constantly on the move. Additionally, fast-charging capabilities ensure that the device can be quickly recharged, minimizing downtime.

Lastly, the XR500 is designed with a sleek and modern aesthetic, combining form and function. Its lightweight and portable design make it easy to transport, ideal for professionals who need to work on the go. With an emphasis on user experience, the XR500 is not just a deviceā€”it's a comprehensive solution that meets the diverse needs of modern users. Whether you are a professional seeking performance or a consumer looking for quality, the DMP Electronics XR500 is a compelling choice that stands out in the market.