DMP Electronics XR500 manual 18.10.2, Home/Sleep/Away Programming, Area Name, Automatic Arming

Page 55

Area Information

18.10.2

int bdrm perim

18.11* Unused *

18.12Account No: 12345

18.13Auto Arm no YES

18.14Bad Zones: BYP

Byp Forc

Ref

18.15 Auto Dis no YES

Home/Sleep/Away Programming

When Home/Sleep/Away is selected as the system type, program the Interior, Bedroom, and Perimeter areas as needed.

Area Name

The area name can be up to 32 alphanumeric characters. To add an area name to the system, press any Select key and then enter up to 32 characters for the new area name. Press COMMAND to continue. For instructions on entering alphanumeric characters see section 1.7 Entering Alpha Characters. Inactive areas are marked * UNUSED *. Only systems programmed for Area arming have the option available to change the area name.

To mark an active area unused, press any top row Select key to delete the old name, then press the COMMAND key. The programmer automatically programs the name as *UNUSED*. If you have already cleared Area Information during Initialization, all areas are marked * UNUSED *. See Initialization section.

Home/Sleep/Away with Guest systems display the area name, but the names cannot be changed. The following are the display names that appear on the keypad:

Area

Display

 

Area

Display

 

Area

Display

1

Perimeter

 

4

Guest1 Perimeter

 

7

Guest2 Perimeter

2

Interior

 

5

Guest1 Interior

 

8

Guest2 Interior

 

 

 

 

 

 

 

 

3

Bedrooms

 

6

Guest1 Bedrooms

 

9

Guest2 Bedrooms

Account Number

Enter the account number to be sent to the receiver for this area. Choose an account number compatible with the Communication Type selected in Communications. The default Account Number is the one previously entered in Communications. This account number is used when sending area messages and events to the central station. See the Area Account Number Messages in the Appendix.

Automatic Arming

Select YES to allow this area to arm automatically according to permanent, temporary, or extended schedules. If no schedules are programmed, the area auto arms every hour.

If closing check is selected as YES, the automatic arming function does not take place until the expiration of a ten minute Closing Check delay. See Closing Check. If the area has been disarmed outside of any permanent or temporary schedule, the closing check sequence occurs one hour after the area is disarmed.

At arming, bad zones are handled according to the option selected in section Bad Zones. If a closing report is sent, the user number is indicated as SCH on the SCS-1R Receiver. NO disables automatic arming for this area.

Bad Zones

At the time of automatic arming, some zones in the area may not be in a normal condition. This option allows you to program the panel response to these bad zones. This option does not display if AUTO ARM is NO.

BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if Bypass Reports is YES. The report indicates SCH as the user number.

FORC - All bad zones are force armed. Zones force armed in a bad condition are capable of restoring and reporting an alarm if tripped. A forced zone report is transmitted if Bypass Reports is YES. The report indicates SCH as the user number.

REF - The automatic arming is refused and no arming takes place. A No Closing report is sent to the receiver regardless of the Closing Check selection.

Automatic Disarming

NO disables automatic disarming by schedule for this area. When YES is selected, the area automatically disarms according to permanent or temporary schedules. If an opening report is sent to the receiver, the user number is indicated as SCH.

Digital Monitoring Products

XR500 Series Canadian Programming Guide

46

Image 55
Contents Programming Guide Industry Canada Notice Table Of Contents Messaging Setup Bell Options System ReportsOutput Groups Area Information Zone InformationStop Feature UpgradeThis page intentionally left blank Before you Begin IntroductionGetting Started Programmer Lockout Codes Reset TimeoutEncrypted Communications XR500N/XR500E only Programmer OperationKeypads Power UpSpecial Keys Special Characters Entering Alpha CharactersEntering Non-Alpha Characters Keypad Displays Current ProgrammingAsterisks in Programming Multiple DisplaysDevices Areas Initialization Clear Communication and Remote Options Set to Factory DefaultsCommunication Test Day Path TypeTest Report Test FrequencyAdvanced Programming Receiver PortFirst Telephone Number Second Telephone NumberRetry Seconds Setup StringAlarm Switch Duplicate AlarmsOpening/Closing and User Reports Alarm ReportsDoor Access Report Supervisory/Trouble ReportsDNS Server Local IP AddressGateway Address Subnet MaskMessaging Setup Smtp Server Smtp PasswordDestination 3 User Number Email Communication TypeDevice Setup Options and Actions Not Affected Display AreasUser Action Allowed Status Display AllowedOutput Group Strike DelayStrike Time Fire Exit ReleaseActivate Zone 2 Shunt Relock on Zone 2 Fault?15.1 15.2 Program 734 OptionsCustom Card Definitions 15.6 15.7 15.8Activate Onboard Speaker Card OptionsSite Code Display 15.9Require Site Code 15.9 15.10Remote Options Network Programming Port Manufacturer AuthorizationPC Modem Allow Network RemoteEntré Passphrase Entré Backup IP AddressEntré Backup TCP Port Entré CheckinSystem Reports Panic Test Communication XR500N/XR500E only AmbushInstant Arming Entry DelaySystem Options SystemTime Zone Changes Reset Swinger BypassCross Zone Time Swgrbyps Trips 1 Swinger Bypass TripsCity/Time Zone Latch Supervisory ZonesProgramming Menu Language User Menu and Status List LanguageHouse Code Detect Wireless JammingBypass Limit Card Plus PIN XR500E onlyEnhanced Zone Test Wireless Audible AnnunciationEnable Keypad Panic Keys Occupied PremisesBell Options Output Options 11.7 11.8 Panic Alarm OutputSensor Reset Output 11.611.16 Arm-Alarm Output11.15 Closing Wait OutputOutput Information Output Groups Menu Display Status List Panic Zones 15.5 15.6Burglary Zones Supervisory ZonesPrinter Reports PC Log Reports PC Log Real-Time Status Door Acs no YES Door Access Reports17.10 17.11 17.12Area Information Any Bypass 18.5 18.6 18.7 18.8 18.9 18.10Closing Check Closing CodeAutomatic Arming 18.10.2Home/Sleep/Away Programming Area NameBank Safe & Vault XR500N/XR500E only Late Arm DelayArmed Output Number Late Output NumberZone Name Zone Information19.1 Zone Number19.6 Zone Type Specifications19.5 Area AssignmentArming Zone Operation 19.7 19.8Arming Zone Area Assignment StyleNext Zone DMP WirelessWireless 19.9PIR Pulse Count Disarm/Disable19.10.3 19.10.4 19.10.5 19.10.6 19.10.7 19.10.8 LED OperationKey Fob Serial Number Series Key Fobs19.11.1 19.11.2 19.11.3 Key Fob User NumberButton Press Time 19.11.7Button Action 19.11.8Output Action 19.11.10 19.11.11 19.11.12Check-in Time FA Series Wireless 19.12Alarm Action 19.12.1 19.12.2 19.12.3Report to Transmit 19.15 19.16 19.1719.24 Zone Retard DelayPresignal Keypad Addresses 19.23Fire Panel Slave Input 19.25Priority 19.26Set Lockout Code StopSet Lockout Code 21.1Feature Upgrade Diagnostics function False Alarm ReductionAppendix Successful Display Failure Display Cellular Results Successful Display Failure DisplayNetwork Results Successful Display Failure Display Email Results Successful Display Failure DisplayKeypad Displays Using the 984 Command FunctionTrip Counter For Walk Test Using the Walk TestWalk Test Zone TypesKeypad Speaker Operation Trip Counter For DMP Wireless Check-in Test WLSTest End Warning Failed Zones Display23.8 User Profiles Report Type Immediately DelayedCross Zoning 23.7 Events ManagerCross Talk FA Series Transmitter InformationZone Type Specifications Wireless Check-in and Supervision DefinitionsKeypad Bus and LX-Bus Zone Type Descriptions Keypad Bus Zone Information Keypad Bus Zone Type DefaultsZone Type Defaults LX-Bus Zone Type DefaultsCommon Keypad Messages Message Meaning Possible SolutionsArea Account Number Messages Revisions to This Document Listings and Approvals Intrusion Fire Access Networks

XR500 specifications

DMP Electronics has made significant waves in the tech industry with its innovative XR500 device, a cutting-edge solution that caters to both professional and consumer needs. The XR500 combines advanced technologies with a user-friendly design to deliver an exceptional user experience.

One of the standout features of the XR500 is its powerful processing capabilities. Equipped with a high-performance processor, the device ensures seamless multitasking and quick access to applications. This allows users to handle demanding tasks such as gaming, content creation, and data analysis without experiencing lag or slowdown.

In terms of display, the XR500 boasts a stunning high-resolution screen that enhances visual clarity and color accuracy. Whether you are watching videos, playing immersive games, or editing images, the vibrant colors and sharp details make every experience enjoyable. The device also supports high refresh rates, providing fluid motion essential for fast-paced gaming.

Another critical characteristic of the XR500 is its versatility. It features multiple connectivity options including USB-C, HDMI, and Bluetooth, enabling users to connect a wide range of peripherals and accessories. This flexibility makes the XR500 suitable for various applications, whether you're in a creative professional environment or simply enjoying media at home.

DMP has also focused on the XR500's audio quality. Equipped with advanced sound technologies, the device delivers an immersive audio experience. Clear and rich sound enhances gaming and movie-watching experiences, ensuring that every detail is heard. The integrated speakers are supplemented by options for external sound systems, catering to audiophiles and casual listeners alike.

Battery life is a crucial consideration for any electronic device, and the XR500 does not disappoint. It features a robust battery that supports extended usage times, making it ideal for users who are constantly on the move. Additionally, fast-charging capabilities ensure that the device can be quickly recharged, minimizing downtime.

Lastly, the XR500 is designed with a sleek and modern aesthetic, combining form and function. Its lightweight and portable design make it easy to transport, ideal for professionals who need to work on the go. With an emphasis on user experience, the XR500 is not just a deviceā€”it's a comprehensive solution that meets the diverse needs of modern users. Whether you are a professional seeking performance or a consumer looking for quality, the DMP Electronics XR500 is a compelling choice that stands out in the market.