Bryant 551A operation manual Accessory/FIOP Static Pressure in. wg, Drop

Page 24

Table 13 — Accessory/FIOP Static Pressure (in. wg)

UNIT

HEATER

 

ELECTRIC HEATERS

ECONOMI$ER

RATED

CFM

PRESSURE DROP

 

PRESSURE

551A

 

VOLTAGE

 

 

(kW)

 

 

 

DROP

 

 

 

 

 

 

 

 

3,750

0.05 (14/19, 26/34)

0.06 (42/56)

0.07 (56/75)

0.03

 

 

4,000

0.05 (14/19, 26/34)

0.06 (42/56)

0.07 (56/75)

0.04

 

208/240-3-60

5,000

0.07 (14/19, 26/34)

0.08 (42/56)

0.10 (56/75)

0.05

 

6,000

0.09 (14/19, 26/34)

0.12 (42/56)

0.15 (56/75)

0.07

 

 

 

 

7,200

0.11 (14/19, 26/34)

0.16 (42/56)

0.20 (56/75)

0.09

155,180

 

7,500

0.12 (14/19, 26/34)

0.17 (42/56)

0.21 (56/75)

0.10

 

3,750

0.05 (15, 32)

0.06

(55)

 

0.07 (80)

0.03

 

 

 

 

 

4,000

0.05 (15, 32)

0.06

(55)

 

0.07 (80)

0.04

 

480-3-60

5,000

0.07 (15, 32)

0.08

(55)

 

0.10 (80)

0.05

 

6,000

0.09 (15, 32)

0.12

(55)

 

0.15 (80)

0.07

 

 

 

 

 

7,200

0.11 (15, 32)

0.15

(55)

 

0.20 (80)

0.09

 

 

7,500

0.12 (15, 32)

0.17

(55)

 

0.21 (80)

0.10

 

 

5,000

0.08 (26/34)

0.11 (42/56)

 

0.14 (56/75)

0.06

 

 

6,000

0.09 (26/34)

0.12 (42/56)

 

0.15 (56/75)

0.07

 

208/240-3-60

7,200

0.11 (26/34)

0.16 (42/56)

 

0.20 (56/75)

0.09

 

9,000

0.15 (26/34)

0.19 (42/56)

 

0.24 (56/75)

0.11

 

 

 

 

 

10,000

0.17 (26/34)

0.21 (42/56)

 

0.26 (56/75)

0.12

240

 

11,250

0.20 (26/34)

0.24 (42/56)

 

0.29 (56/75)

0.14

 

5,000

0.08 (32)

0.11 (55)

0.14 (80)

0.06

 

 

 

 

6,000

0.09 (32)

0.12 (55)

0.15 (80)

0.07

 

480-3-60

7,200

0.11 (32)

0.15 (55)

0.20 (80)

0.09

 

9,000

0.15 (32)

0.19 (55)

0.24 (80)

0.11

 

 

 

 

10,000

0.17 (32)

0.21 (55)

0.26 (80)

0.12

 

 

11,250

0.20 (32)

0.24 (55)

0.29 (80)

0.14

LEGEND

FIOP — Factory-Installed Option

NOTES:

1.Heaters are rated at 240 v, and 480 v.

2.The factory assembled horizontal adapter substantially improves fan performance.

3.The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should then be used in conjunction with the Fan Performance table to determine blower rpm, bhp, and watts.

Fig. 29 — Perfect Humidity™ Operation Diagram

24

Image 24
Contents Contents Safety ConsiderationsInstallation Provide Unit Support II. RIG and Place UnitRoof Curb Details Unit Maximum Dimensions Shipping Weight Ft-in 155180 240Unit STD Unit ECONOMI$ER Corner DIM a DIM B DIM C Weight 551AFt-in 155 1575 714 36.3 407 185 375 170 383 174 410 1039 1054 559 180 1650 748 36.3 375 170 449 204 452Base Unit Dimensions, 551A240 Physical Data 155 180 240III. Field Fabricate Ductwork IV. Make Unit Duct ConnectionsTrap Condensate Drain 551A180 and 240 Shown 551A155 ShownField Control Wiring Unit VoltageNEC Electrical Data FLA LRA MCA MOCP†Electric Resistance Heater Data UnitHeater Maximum Minimum Heater Amps PERVII. Make OUTDOOR-AIR Inlet Adjustments Optional Non-Fused DisconnectOptional Convenience Outlet Manual Outdoor-Air DamperHeat Anticipator Settings VIII. Install OUTDOOR-AIR HoodOutdoor Air Enthalpy Sensor Installation Unit StageCO2 Control Setup Discharge Air Thermistor DATDry Bulb Changeover Set Up EconoMi$er Switchover Control StrategyDefault Potentiometer Settings Mechanical Cooling LockoutVentilation Air Minimum Position Set Up IX. Install ALL AccessoriesMotormaster I Control Installation 551A155 and 180 Only Motormaster III Control Installation 551A240 Only Wind Baffle DetailsLlsv LPSIII. Refrigerant Service Ports Internal WiringXI. Accessory ECONOMI$ER Adjustment START-UPFreeze Protection Thermostats Units With Perfect Humidity Dehumidification PackageFan Performance 551A155 With Standard Indoor Fan Motor Cfm Rpm Watts Bhp Watts BhpWatts Bhp Rpm 3750 551A180 15 Tons 48005100 5700551A240 20 Tons Watts Bhp RpmBhp Rpm Watts 000 500Accessory/FIOP Static Pressure in. wg DropFan RPM at Motor Pulley Settings Evaporator Fan Motor SpecificationsService Cleaning IV. Evaporator FAN Service and ReplacementII. Lubrication Evaporator-Fan Pulley Alignment Adjustment Belt Tension AdjustmentVI. CONDENSER-FAN Adjustment VII. ECONOMI$ER AdjustmentVIII. Power Failure IX. Refrigerant ChargeFilter Drier XI. Protective DevicesXIV. Replacement Parts XVI. Optional Hinged Access DoorsXII. Relief Devices XIII. Control CircuitTypical Wiring Schematic 551A180, 460v Shown Typical Component Arrangement 551A180 Shown Troubleshooting Cooling Service AnalysisProblem Cause Remedy EconoMi$er Troubleshooting Problem Potential Cause RemedyPage Temperatures ElectricalGeneral