Desa CGCFTP, CGCFTN installation manual Fireplace pilot and burner must be at least 18 above floor

Page 10

INSTALLation

Continued

CAUTION: This fireplace cre- ates warm air currents. These currents move heat to wall sur- faces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fire- place in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

Note: When installing fireplace directly on carpet- ing, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.

CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18" above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspec- tion and service.

in coldest part of room

An optional blower kit is available from your dealer. See Accessories, page 27. If planning to use blower, locate fireplace near an electrical outlet.

Built-In Fireplace Installation

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accessories, page 27). Brass trim will extend past sides of fireplace approximately 1/2". This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 12, page 12. Follow the instructions below to install the fireplace in this manner. Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides or top of your fireplace.

 

Actual

Framing

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

9 1/2"

10 1/2"

Bottom

3/4"

3/4"

1.Frame in rough opening. Use dimensions shown in Figure 8 for the rough opening.

If installing in a corner, use dimensions shown in Figure 9 for the rough opening. The height is 26 7/8" which is the same as the wall opening above.

10 1/2"

267/8"

3/4" Off

The Floor

267/8" Minimum

Figure 8 - Rough Opening for Installing

in Wall

365/8"

257/8"

267/8" 513/4"

Figure 9 - Rough Opening for Installing

in Corner

10

www.desatech.com

111044-01J

Image 10
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety InformationSafety Information Poisoning may lead to deathProduct Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Providing Adequate Ventilation AssemblyAir For Combustion Ventilation Assembling HoodConfined and Unconfined Space Determining FRESH-AIR Flow for fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Built-In Fireplace Installation Fireplace pilot and burner must be at least 18 above floorCheck all gas connections for leaks. See If you have not assembled firebox, follow instructions onChecking Gas Connections, Installing blower accessory GA3450TA Mantel Clearances for Built- In InstallationOptional Mantel Installation Removing Upper Louver AssemblyInstalling Blower Assembly Models Cgcftp and CgcftnReinstall valve cover shield Connecting to GAS SupplyFor Built-In Installation Extension CordAccessories, Natura LChecking GAS Connections Connecting Equipment shutoff valve to heater controlInstallation Items Needed Checking Gas ConnectionsCorrect all leaks at once Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOperating Fireplace Thermostat Control OperationPilot Flame Pattern Cleaning MaintenanceInspecting Burner Burner Flame PatternAir Passageways CabinetExterior Troubleshooting Observed Problem Possible Cause RemedyTroubleshooting MaintenanceSee Cleaning and Mainte Maintenance,Gas leak. See Warning See Checking Gas ConnecTechnical Service SpecificationsService Hints Replacement PartsBrass Trim KIT GA6095 AccessoriesEquipment Shutoff Valve GA5010 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA14 29 Parts List Parts Centrals 111044-01J Limited Warranty Warranty InformationKeep this Warranty VENT-FREE Compact fireplace