Desa HDCFTP, HDCFTN, CGCFTP, CGCFTN Installing Blower Assembly, Models Cgcftp and Cgcftn

Page 13

 

INSTALLation

6. Route the wire harness through the hole in

 

Continued

left side of baffle. Pull wire harness through

 

 

 

lower opening above where the valve shield

 

 

Branch

was removed. (see Figure 14).

Shoulder Screw

Support

7. Insert the 4 wire harness into one of the round

 

 

 

holes in the rear of the valve cover shield and

 

Valve

 

through the rectangular hole in the front of

Remove

Cover

 

shield (see Figure 14).

Shield

 

8. Reconnect red wire to switch position 3.

Screw

 

 

Reconnect blue wire to switch position 1.

 

 

 

Reconnect green and white wires.

 

 

 

9. Install the switch plate on the valve cover shield

 

 

 

with 2 #10 screws provided (see Figure 15).

 

 

 

Reinstall the valve cover shield. Route power

 

 

 

cord out of the cabinet by inserting it through the

 

 

 

bushing on the outer casing (see Figure 14). Plug

 

 

Bottom Louver

fan kit into 120-Volt grounded power supply and

Snap Bushings

Assembly

test operation. Note: When switch is in theAUTO

Figure 13 - Removing Valve Cover Shield

position, the fan will start after the heater has run

for a few moments. The fan will continue to run for

Installing Blower Assembly

several moments after the heater has been turned

(Models CGCFTP and CGCFTN)

off. When switch is in the ON position, the fan

 

 

 

will run until turned to OFF. Reinstall upper louver

CAUTION: Label all wires

assembly and hood if previously removed, (see

Figure 12, page 12). Close lower louver door.

prior

to disconnection when

 

 

servicing controls. Wiring errors

Blower Bracket

Wire Harness

can cause improper and danger-

Assembly

Wiring Routing

ous operation.

 

Screw

Hole in Baffle

CAUTION: Verify proper op- eration after servicing.

Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In Installation on page 14.

1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.

2.Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly.

3.Note the wire locations on back of AUTO/ OFF/ON switch. The terminals on back of switch are numbered 1, 2 and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 14).

4.Carefully disconnect green and white wires at their insulated connectors.

5.In top of the heater cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 #10 screws provided (see Figure 14).

Baffle

Switch Power

Cord

Red

Switch

Plate

Blue

Wire

Valve Cover Shield BoxCover Harness

Figure 14 - Installing Blower Bracket

Assembly

Valve

Cover

Shield

Switch Plate

Screw

Figure 15 - Installing Switch Plate to

Valve Cover Shield

111044-01J

www.desatech.com

13

Image 13
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Safety Information Table of ContentsPoisoning may lead to death Safety InformationProduct Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Air For Combustion Ventilation AssemblyProviding Adequate Ventilation Assembling HoodConfined and Unconfined Space Determining FRESH-AIR Flow for fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Fireplace pilot and burner must be at least 18 above floor Built-In Fireplace InstallationCheck all gas connections for leaks. See If you have not assembled firebox, follow instructions onChecking Gas Connections, Optional Mantel Installation Mantel Clearances for Built- In InstallationInstalling blower accessory GA3450TA Removing Upper Louver AssemblyModels Cgcftp and Cgcftn Installing Blower AssemblyFor Built-In Installation Connecting to GAS SupplyReinstall valve cover shield Extension CordNatura L Accessories,Installation Items Needed Connecting Equipment shutoff valve to heater controlChecking GAS Connections Checking Gas ConnectionsCorrect all leaks at once Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Fireplace For Your Safety Read Before LightingLighting Instructions Operating Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning MaintenancePilot Flame Pattern Burner Flame PatternAir Passageways CabinetExterior Observed Problem Possible Cause Remedy TroubleshootingMaintenance TroubleshootingMaintenance, See Cleaning and MainteSee Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsEquipment Shutoff Valve GA5010 AccessoriesBrass Trim KIT GA6095 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA14 29 Parts List Parts Centrals 111044-01J Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact fireplace