Desa HDCFTP, HDCFTN, CGCFTP, CGCFTN installation manual 14 29

Page 28

Illustrated Parts Breakdown

Models CGCFTP, CGCFTN, HDCFTP AND HDCFTN

45

42

7

4

10

9

8 17

31

30

4

20

4

7

11

8

33

14 29 24

2512-1

23

35

 

 

13

 

8

 

 

14

32

 

 

 

 

39

 

 

37

 

 

 

 

 

 

19

 

 

 

 

 

 

41

 

 

 

38

34

5

6

 

 

12

 

 

43

 

 

25

 

 

 

 

28

24

 

26 18

36

 

15

39

 

 

 

22

 

 

 

44 27

21

 

 

 

 

40

 

16

 

 

 

 

 

 

 

 

31

8

3

2

28

www.desatech.com

111044-01J

Image 28
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Table of Contents Safety InformationSafety Information Poisoning may lead to deathProduct Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Assembly Air For Combustion VentilationProviding Adequate Ventilation Assembling HoodConfined and Unconfined Space Determining FRESH-AIR Flow for fireplace LocationDetermining if You Have a Confined or Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Built-In Fireplace Installation Fireplace pilot and burner must be at least 18 above floorCheck all gas connections for leaks. See If you have not assembled firebox, follow instructions onChecking Gas Connections, Mantel Clearances for Built- In Installation Optional Mantel InstallationInstalling blower accessory GA3450TA Removing Upper Louver AssemblyInstalling Blower Assembly Models Cgcftp and CgcftnConnecting to GAS Supply For Built-In InstallationReinstall valve cover shield Extension CordAccessories, Natura LConnecting Equipment shutoff valve to heater control Installation Items NeededChecking GAS Connections Checking Gas ConnectionsCorrect all leaks at once Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Fireplace For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Operating FireplaceTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning Maintenance Inspecting BurnerPilot Flame Pattern Burner Flame PatternAir Passageways CabinetExterior Troubleshooting Observed Problem Possible Cause RemedyTroubleshooting MaintenanceSee Cleaning and Mainte Maintenance,Gas leak. See Warning See Checking Gas ConnecSpecifications Service HintsTechnical Service Replacement PartsAccessories Equipment Shutoff Valve GA5010Brass Trim KIT GA6095 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA14 29 Parts List Parts Centrals 111044-01J Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Compact fireplace