Desa HDCFTP, HDCFTN, CGCFTP, CGCFTN Gas leak. See Warning, See Checking Gas Connec

Page 25

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Fireplace produces unwanted

1.

Fireplace burning vapors from

1.

Ventilate room. Stop using

odors

 

paint, hair spray, glues, etc.

 

odor causing products while

 

 

(see IMPORTANT statement

 

fireplace is running

 

2.

above)

2.

Refill supply tank

 

Low fuel supply

 

3.

Gas leak. See Warning

3.

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

 

Fireplace shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

2.

able

2.

ventilation

 

Low line pressure

Contact local propane/LP or

 

3.

O D S / p i l o t i s p a r t i a l l y

3.

natural gas company

 

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 20)

 

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve defective

2.

tions, page 16)

 

Replace control valve

 

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

2.

trol valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 6)

111044-01J

www.desatech.com

25

Image 25
Contents HDCFTP, HDCFTN, Cgcftp and Cgcftn Shown with Optional Cabinet Mantel/Hearth Base Accessory14,000 to 26,000 Btu/Hr with Thermostat Safety Information Table of ContentsPoisoning may lead to death Safety InformationProduct Information Local CodesProvide adequate clearances around air openings Assembly Product FeaturesUnpacking Air For Combustion Ventilation AssemblyProviding Adequate Ventilation Assembling HoodConfined and Unconfined Space Determining FRESH-AIR Flow for fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace Fireplace pilot and burner must be at least 18 above floor Built-In Fireplace InstallationCheck all gas connections for leaks. See If you have not assembled firebox, follow instructions onChecking Gas Connections, Optional Mantel Installation Mantel Clearances for Built- In InstallationInstalling blower accessory GA3450TA Removing Upper Louver AssemblyModels Cgcftp and Cgcftn Installing Blower AssemblyFor Built-In Installation Connecting to GAS SupplyReinstall valve cover shield Extension CordNatura L Accessories,Installation Items Needed Connecting Equipment shutoff valve to heater controlChecking GAS Connections Checking Gas ConnectionsCorrect all leaks at once Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Operating Fireplace For Your Safety Read Before LightingLighting Instructions Operating Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning MaintenancePilot Flame Pattern Burner Flame PatternAir Passageways CabinetExterior Observed Problem Possible Cause Remedy TroubleshootingMaintenance TroubleshootingMaintenance, See Cleaning and MainteSee Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsEquipment Shutoff Valve GA5010 AccessoriesBrass Trim KIT GA6095 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA14 29 Parts List Parts Centrals 111044-01J Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact fireplace