Desa CGCFTP, CGCFTN Specifications, Service Hints, Technical Service, Replacement Parts

Page 26

Specifications

HDCFTP, CGCFTP

Rating (Variable): 14,000/26,000 Btu

Gas Type: Propane/LP Only

Ignition: Piezo

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (in. of water)*: Maximum - 14", Minimum - 11"

Dimensions (H x W x D) Fireplace - 25 7/8" x 26 13/16" x 9 3/8" Carton - 32 5/8" x 27 3/16" x 11 5/8"

Weight: Fireplace - 44.5 lbs, Shipping - 48 lbs * For purposes of input adjustment

HDCFTN, CGCFTN

Rating (Variable): 14,000/26,000 Btu

Gas Type: Natural Only

Ignition: Piezo

Pressure Regulator Setting: 3" W.C.

Inlet Gas Pressure (in. of water)*: Maximum - 10.5", Minimum - 5"

Dimensions (H x W x D) Fireplace - 25 7/8" x 26 13/16" x 9 3/8" Carton - 32 5/8" x 27 3/16" x 11 5/8"

Weight: Fireplace - 44.5 lbs, Shipping - 48 lbs * For purposes of input adjustment

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low (propane/LP only)

You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Products’Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’techni- cal service web site at www.desatech.com.

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products’ Technical Service Department at 1-866-672-6040 for referral in- formation.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product or Parts Central (see page 30). If they can’t supply original replacement part(s) call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready:

model number of your fireplace

the replacement part number

26

www.desatech.com

111044-01J

Image 26
Contents 14,000 to 26,000 Btu/Hr with Thermostat Shown with Optional Cabinet Mantel/Hearth Base AccessoryHDCFTP, HDCFTN, Cgcftp and Cgcftn Table of Contents Safety InformationSafety Information Poisoning may lead to deathProvide adequate clearances around air openings Local CodesProduct Information Unpacking Product FeaturesAssembly Providing Adequate Ventilation AssemblyAir For Combustion Ventilation Assembling HoodDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for fireplace LocationConfined and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsLocating Fireplace Installation ItemsCheck GAS Type Built-In Fireplace Installation Fireplace pilot and burner must be at least 18 above floorChecking Gas Connections, If you have not assembled firebox, follow instructions onCheck all gas connections for leaks. See Installing blower accessory GA3450TA Mantel Clearances for Built- In InstallationOptional Mantel Installation Removing Upper Louver AssemblyInstalling Blower Assembly Models Cgcftp and CgcftnReinstall valve cover shield Connecting to GAS SupplyFor Built-In Installation Extension CordAccessories, Natura LChecking GAS Connections Connecting Equipment shutoff valve to heater controlInstallation Items Needed Checking Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsCorrect all leaks at once Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureOperating Fireplace Thermostat Control OperationPilot Flame Pattern Cleaning MaintenanceInspecting Burner Burner Flame PatternExterior CabinetAir Passageways Troubleshooting Observed Problem Possible Cause RemedyTroubleshooting MaintenanceSee Cleaning and Mainte Maintenance,Gas leak. See Warning See Checking Gas ConnecTechnical Service SpecificationsService Hints Replacement PartsBrass Trim KIT GA6095 AccessoriesEquipment Shutoff Valve GA5010 THERMOSTATICALLY-CONTROLLED Blower KIT GA3450TA14 29 Parts List Parts Centrals 111044-01J Limited Warranty Warranty InformationKeep this Warranty VENT-FREE Compact fireplace