INSTALLATION
Continued
Note: All vertical |
| Mantel Shelf | |||
measurements | 10" |
|
|
|
|
are from top | 8" |
|
|
|
|
|
|
|
| ||
of fireplace | 6" |
|
|
|
|
|
|
|
| ||
opening to |
|
|
|
| |
2 1/2" |
|
|
|
| |
bottom of |
|
|
|
| |
|
|
|
|
| |
mantel shelf. |
|
|
|
|
|
Minimum Non- |
|
|
|
|
|
Combustible |
|
|
|
|
|
Material | 13" | 16" | 19" | 21" |
|
|
| ||||
|
|
|
|
|
|
Figure 16 - Minimum Mantel Clearances
for
INSTALLING GAS PIPING TO FIREPLACE LOCATION
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.
CAUTION:Neverconnectpro- pane/LP fireplace directly to the propane/LPsupply.Thisfireplace
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
•external regulator for propane/LP unit only (supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap (optional)
•tee joint
•pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes) (not provided)
*A CSA
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 17. Pointing the vent down protects it from freezing rain or sleet.
CAUTION: Use only new, black iron or steel pipe. Inter-
requires an external regulator (notsupplied).Installtheexternal regulator between the fireplace and propane/LP supply.
WARNING: Never connect natural gas fireplace to private
External |
Regulator |
Vent |
Pointing |
Down |
Propane/LP Supply Tank
wellhead gas.
Figure 17 - External Regulator with Vent
Pointing Down
www.desatech.com | 13 |