OPERATING FIREPLACE

Continued

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burners.

11.Set flame adjustment knob to any level between HI and LO.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

 

 

Electrode

Figure 33 - Pilot (Natural)

Pilot Burner

 

 

Ignitor

 

Electrode

Figure 34 - Pilot (Propane/LP)

TO TURN GAS OFF

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page

34). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 19.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 35, page 21). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

20

www.desatech.com

107172-01K

Image 20
Contents What to do if YOU Smell GAS Table of Contents Safety Information Log Base Assembly Product IdentificationUnpacking Product FeaturesLocal Codes Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationCheck GAS Type Assembling and Attaching Optional Brass Trim Installing HoodElectrical Hookup Installation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Installing Cabinet MantelRaise the mantel to an accept- able height Remove the mantel Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Propane/LPTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsNatural Gas Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressurize supply piping system by eitherInstalling Front Log Front Log Notch Grate Prongs Metal Grate Bars Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Manual Lighting Procedure To Turn GAS OFF To ApplianceOptional HAND-HELD Remote Operation Shutting Off HeaterAuto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Models Ghrcb and CghrcbKey Pad Lock Feature Inspecting BurnersOptional Blower Operation Pilot Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceFront Burner Flame Pattern Wiring Diagram SpecificationsTroubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Maintenance, Gas leak. See Warning Stalling Logs,Replacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Perimeter Trim Accessory Receiver and Remote Control KIT Ghrcb CghrcbWALL-MOUNT ON/OFF Switch Corner Hearth BaseLimited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty