Desa BHDV41N/P, BHDV37N/P DIRECT-VENT Fireplace NATURAL/PROPANE/LP, Safety Information

Page 2

® (B)HDV37N/P AND (B)HDV41N/P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and ser- viced by a qualified service person. Some people are more affected by carbon monox- ide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high tempera- tures. Keep children and adults away from hot surfaces to avoid burns or cloth- ing ignition. Fireplace will remain hot for a time after shut-down. Allow sur- faces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to op- erating fireplace.

8.Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should in- stall, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annu- ally by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Mainte- nance, page 29.

11.Keep the area around your fireplace clear of combustible materials, gaso- line, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire- place nameplate.

14.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANS/NFPA 70, or the Cana- dian Electrical Code, CSA C22.1.

15.Do not obstruct the flow of combus- tion and ventilation air in any way. Pro- vide adequate clearances around air openings into the combustion chamber along with adequate accessibility clear- ance for servicing and proper operation.

16.Do not install fireplace directly on car- peting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel ex- tending the full width and depth of the fireplace.

17.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to ar- range for replacement of the unit.

18.Do not operate fireplace if any log is broken.

19.Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this fireplace.

20.Do not operate fireplace with glass door removed, cracked, or broken.

2

104558

Image 2
Contents BHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting Vanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingInstalling GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypePlug in blower power cord Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Back View of Thermostat BaseREMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips HDV OnlyInstalling Optional Brick Liner D8037/D8041 Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Fireplace Models BHDV37N/P and BHDV41N/PInstalling Log Assembly No Fireplace Models HDV37N/P and HDV41N/POperating Fireplace Ghrct Series Operation Operating Optional Blower AccessoryGhrc Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Pilot AssemblyInspecting Burners Burner Flame PatternPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSpecifications BHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41PAccessories Illustrated Parts Breakdown BHDV37N BHDV41N36Parts List DIRECT-VENT Fireplace BHDV37N BHDV41NBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.