1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON po-

sition. Turn variable control knob

anywhere between HI and LO. Slide

the selector switch to the REMOTE

position. Note: The burner(s) may

light if hand-held remote ON button

was on when selector switch was last

turned off. You can now turn the

burner(s) on and off with either op-

tional hand-held remote control unit.

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

remote control unit for up to 3 sec-

IMPORTANT: The hand-held re- mote control unit must be near the heater but not extremely close to it. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used.

4.To turn the burner(s) off when oper- ating in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the gas con- trol knob on the heater to the OFF position or set selector switch to OFF position.

Blower Control Knob Variable

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

Both the GA3700 manual blower and the DA3610T thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610T Only: If you are using DA3610T blower with optional ther- mostat (wall mount or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot

onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

(Optional Accessory)

OFF

ON

Control Knob

position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air

burner(s) on and off. When turning burner(s) off, the pilot will remain lit.

GHRCT Series Operation:

2b. Select the MAN (manual) or AUTO button on the hand-held remote con- trol unit (see Figure 59).

In manual mode, turn burner(s) on

or off by pressing the ON or OFF

buttons on the hand-held remote

control unit.

 

 

N

 

L

 

 

 

O

 

O

I

ON OFF REMOTE

T

F

O

H

O

 

 

 

 

F

 

 

 

 

LIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Control

Control Selector Switch in Knob in On

Remote Position (Optional Position

Remote Control)

Figure 58 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

• In auto mode, the room tempera-

ture is controlled by the thermo-

stat in the hand-held remote con-

trol unit. To increase the room tem-

perature, press the top arrow of the

TEMP button. To lower the room

temperature, press the bottom ar-

row of the TEMP button. At higher

settings the heater will run more.

IMPORTANT: This remote control

has been specially engineered to

take an air temperature sample

Shows Temperature Setting

Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.

The Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

every 5.5 minutes in the auto mode.

It will not respond immediately to

the temperature setting being

turned up or down.

Figure 59 - Hand-Held Thermostat Remote Control Unit Selections (GHRCT Only)

Continued

104558

27

Image 27
Contents For Your Safety For Your Safety What to do if YOU Smell GASBHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationClearances Location and Space RequirementsLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Horizontal H 1 + Min Max 20 max Vertical Termination ConfigurationsVertical Venting Vanguard Flexible Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersPlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsBack View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1Attaching Magnetic Decorative Brass Strips HDV Only REMOVING/REPLACING Glass DoorInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037/D8041Fireplace Models BHDV37N/P and BHDV41N/P Installing LOGS, Lava Rock and Glowing EmbersFireplace Models HDV37N/P and HDV41N/P Installing Log Assembly NoOperating Fireplace Operating Optional Blower Accessory Ghrc Series OperationGhrct Series Operation Burner Flame Pattern Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsWiring Diagram Technical ServiceBHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41P SpecificationsAccessories BHDV37N BHDV41N36 Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV37N BHDV41N Parts ListBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.