Desa BHDV41N/P, BHDV37N/P installation manual BHDV37P BHDV41P36

Page 38

® (B)HDV37N/P AND (B)HDV41N/P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

ILLUSTRATED

PARTS

BREAKDOWN

BHDV37P

BHDV41P36

7

34-3

34-4

34-2

41

6

34-1

25

29

6

20

18

35

19

53

49

48

26

27

2

11 (Included in Hardware Pack)

47

1

44

37

6

4

35

45

7

24

40

30

 

6

42

43

35

22

21

5

10

16

 

 

 

 

31

 

 

 

 

28

 

 

 

 

 

39

 

 

13

 

 

14

12

 

 

 

23 17

28

38

15

 

9

 

5

8

5

 

 

 

 

50

32

51

52 33

3

46

38

104558

Image 38
Contents BHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting Vanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingInstalling GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypePlug in blower power cord Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Back View of Thermostat BaseREMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips HDV OnlyInstalling Optional Brick Liner D8037/D8041 Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Fireplace Models BHDV37N/P and BHDV41N/PInstalling Log Assembly No Fireplace Models HDV37N/P and HDV41N/POperating Fireplace Ghrct Series Operation Operating Optional Blower AccessoryGhrc Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Pilot AssemblyInspecting Burners Burner Flame PatternPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSpecifications BHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41PAccessories Illustrated Parts Breakdown BHDV37N BHDV41N36Parts List DIRECT-VENT Fireplace BHDV37N BHDV41NBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.