Desa HDV37N/P, BHDV41N/P High Altitude Installation, Parts Lists for Venting Kits and Components

Page 15

OWNER’S MANUAL

VENTING INSTALLATION

Continued

HIGH ALTITUDE

INSTALLATION

Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet.

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help de- termine the proper orifice for your location.

For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Services Department at 1-800-DESA- LOG (1-800-337-2564).

PARTS LISTS FOR VENTING KITS AND COMPONENTS

Vanguard Rigid Venting

Number

Description

 

BGFVK

Basic Ground Floor Rigid Vent Kit

 

Includes: 7" x 60° Elbow, Ex-

 

tended Adjustable Horizontal

 

Termination, Wall Thimble and

 

14 Screws

GFVK

Ground Floor Rigid Vent Kit

 

Includes: 7" x 60° Elbow, 7"

 

Adjustable Galvanized Coaxial

 

Pipe (7-12"), Wall Thimble,

 

Horizontal Termination, RTV

 

Silicone and 16 Screws

BVK

Basement Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 90° El-

 

bow, 7" Adjustable Galvanized

 

Pipe (7-12"), Wall Thimble,

 

Horizontal Termination, RTV

 

Silicone and 20 Screws

Vanguard Rigid Venting (Cont.)

Number Description

SVK

Snorkel Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 90° El-

 

bow, 7" Adjustable Galvanized

 

Pipe (7-12"), Wall Thimble, 36"

 

Snorkel Termination, RTV Sili-

 

cone and 28 Screws

RVF

Roof Rigid Vent Kit

 

Includes: Flue Restrictor, Storm

 

Collar, 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 2' Galva-

 

nized Pipe, 7" Adjustable Gal-

 

vanized Pipe (7-12"), Firestop

 

Support, Roof Flashing, RTV

 

Silicone, Vertical Termination,

 

and 26 screws

D1000

7" x 12" Galvanized Coaxial

 

Pipe (6 pcs.)

D1010

7" x 24" Galvanized Coaxial

 

Pipe (6 pcs.)

D1020

7" x 48" Galvanized Coaxial

 

Pipe (6 pcs.)

D1030

7" Adjustable (7-12")

 

Galvanized Coaxial Pipe

 

(6 pcs.)

D1050

7" x 6" Galvanized Coaxial

 

Pipe (6 pcs.)

D2000

7" x 90° Elbow (6 pcs.)

D2010

7" x 45° Elbow (6 pcs.)

D2020

7" x 30° Elbow (6 pcs.)

D2030

7" x 60° Elbow (6 pcs.)

D3000

Wall Strap/Offset Support

 

(6 pcs.)

D3010

Storm Collar (6 pcs.)

D3020

Wall Thimble (6 pcs.)

D3050

Vertical Restrictor (6 pcs.)

D3060

Ceiling Firestop/Support

 

(6 pcs.)

D3070

Rectangular Horizontal Rigid

 

Vent Termination Cap

D3090

Cathedral Ceiling Support

 

Box

D4000

Roof Flashing 6/12-9/12

D4010

Roof Flashing 9/12-12/12

D4020

Flex Connector (6 pcs.)

D4030

Flex Wall Thimble (6 pcs.)

D4040

4" Hose Clamp (6 pcs.)

D4050

7" Hose Clamp (6 pcs.)

D5000

Wood/Vinyl Siding Standoff

 

(6 pcs.)

Vanguard Flexible Venting

Number Description

BFGFVK Basic Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 2'

Flexible Pipe, 4" x 2' Flexible

Pipe, Wall Thimble, Horizontal

Termination, (2) Spacer Springs,

(2)4" Hose Clamps, (2) 7" Hose Clamps, and 10 Screws

FGFVK Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 4'

Flexible Pipe, 4" x 4' Flexible

Pipe, Wall Thimble, Horizontal

Termination, (4) Spacer Springs,

(2)4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws

D1040 7" x 25' Coaxial Flex Pipe

with Spacer Springs

D3080 Rectangular Horizontal

Flex Termination Cap

SIMPSON DURA-VENT GS 4" x 6 5/8 "

Number Description

Available from DESA International:

SD2040 Simpson Dura-Vent GS

30° Elbow (6 pcs.)

SD2050 Simpson Dura-Vent GS

60° Elbow (6 pcs.)

AvailablefromSimpsonDura-Ventonly:

9027" x 48" Pipe

9037" x 36" Pipe

9047" x 24" Pipe

9067" x 12" Pipe

9077" x 9" Pipe

9087" x 6" Pipe

9117" Adjustable (11"-14 5/8") Pipe

940Wall Thimble

941Cathedral Ceiling Support Box

943Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12

9457" x 45° Elbow

950Vinyl Siding Standoff

953Storm Collar

963Ceiling Firestop

98136" Snorkel Termination

984HorizontalTerminationVentCap

988Wall Strap

9907" x 90° Elbow

991Vertical High Wind Termination

104558

15

Image 15 Contents
For Your Safety For Your Safety What to do if YOU Smell GASBHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationClearances Location and Space RequirementsLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination Configurations Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Horizontal H 1 + Min Max 20 max Vertical Termination ConfigurationsVertical Venting Vanguard Flexible Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersPlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsBack View of Thermostat Base Installing Optional Wall Mounted Thermostat GWMT1Attaching Magnetic Decorative Brass Strips HDV Only REMOVING/REPLACING Glass DoorInstalling Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037/D8041Fireplace Models BHDV37N/P and BHDV41N/P Installing LOGS, Lava Rock and Glowing EmbersFireplace Models HDV37N/P and HDV41N/P Installing Log Assembly NoOperating Fireplace Operating Optional Blower Accessory Ghrc Series OperationGhrct Series Operation Burner Flame Pattern Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsWiring Diagram Technical ServiceBHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41P SpecificationsAccessories BHDV37N BHDV41N36 Illustrated Parts BreakdownDIRECT-VENT Fireplace BHDV37N BHDV41N Parts ListBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information