Desa BHDV41N/P, BHDV37N/P installation manual Operating Fireplace

Page 26

® (B)HDV37N/P AND (B)HDV41N/P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information in column one.

2.Open lower louver panel.

3.Turn ON/OFF switch to “OFF”.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and

turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column one. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not require ac- cessing for lighting.

8.Turn gas control knob counterclock-

wise to “PILOT”.

9.Push in gas control knob all the way and hold. Immediately light the pi- lot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when relea sed, stop and immedi- ately call your service technician or gas supplier.

If the pilot will not stay lit after sev- eral tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Turn gas control knob counterclock-

wise to “ON”.

11.Turn on all electric power to the fireplace.

12.Turn the ON/OFF switch to ON position.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2a. Turn ON/OFF switch to “OFF”.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

Gas Control Knob Variable Control Knob

Piezo

Ignitor

IL T

IH

O

 

P

O

F

N

F

 

O

 

 

LO

Figure 57 - Control Valve

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and

turn clockwise to "OFF".

5.Close lower louver panel.

Shutting Off Burner(s) Only (pilot stays lit)

You may shut off the burner(s) and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Move the wall switch to the OFF position.

3.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/ Replacing Glass Door, page 22).

2.Follow steps 1 through 8 under Light- ing Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release gas control knob. Now follow steps 10 through 14, column 2.

5.Replace glass door (see Removing/ Replacing Glass Door, page 22).

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (See Accessories on page 35). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCT Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burner(s) will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions.

26

104558

Image 26
Contents BHDV37N/P, HDV37N/P BHDV41N/P, and HDV41N/P For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVertical Venting Vanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingInstalling GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypePlug in blower power cord Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Back View of Thermostat BaseREMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips HDV OnlyInstalling Optional Brick Liner D8037/D8041 Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Fireplace Models BHDV37N/P and BHDV41N/PInstalling Log Assembly No Fireplace Models HDV37N/P and HDV41N/POperating Fireplace Ghrct Series Operation Operating Optional Blower AccessoryGhrc Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Pilot AssemblyInspecting Burners Burner Flame PatternPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSpecifications BHDV/HDV37N BHDV/HDV37P BHDV/HDV41N BHDV/HDV41PAccessories Illustrated Parts Breakdown BHDV37N BHDV41N36Parts List DIRECT-VENT Fireplace BHDV37N BHDV41NBHDV37P BHDV41P36 DIRECT-VENT Fireplace BHDV37P BHDV41P HDV37N DIRECT-VENT Fireplace HDV37N and HDV41N HDV37P HDV41P DIRECT-VENT Fireplace HDV37P and HDV41P Warranty Information

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.