Error Codes8ā€“14
Execute Errors
70 EXECUTE form count parameter FC error
This error occurs when the parameter specifying the number of blank forms
to print was entered incorrectly. When this error occurs, the IGP/PGL will
automatically revert to the Normal mode. Form count can be from 1 to
65,535.
71 EXECUTE/DELETE form not found in the directory
An attempt was made to execute or delete a form which does not exist in the
forms directory. When this error occurs, the IGP/PGL reverts to the Normal
mode.
72 EXECUTE EVFU load error
This error is generated only during the Execute Form mode while
programming the EVFU. If more channels than lines per physical page are
specified during a load sequence, this error is generated, and the IGP/PGL
automatically reverts to the Normal mode.
73 EXECUTE EVFU terminator invalid
This error is generated only during the Execute Form mode. The EVFU
LOAD is missing an END LOAD code. If the line terminator cannot be
deciphered, an error is generated, and the IGP/PGL reverts to the Normal
mode.
74 EXECUTE form too wide for current page setting
The form was defined in one orientation while sent to print in another
orientation. Use the debug slash (/) when creating a form to show which
element is out of bounds (see page Cā€“2).
75 EXECUTE form too long for current page setting
The form was defined in one orientation while sent to print in another
orientation. Use the debug slash (/) when creating a form to show which
element is out of bounds (see page Cā€“2).
76 EXECUTE page number error
An error was made while specifying the page number used with the form
being executed. This error can be generated because of incorrect format or a
page number that is too large. The specified page number can range from 0
to 99,999,999. Since the page number is part of the Execute command, the
IGP/PGL will automatically revert to the Normal mode.