Hn[.m]

Optional parameter to adjust the overall height

 

(vertical expansion) of the bar code symbol (including

 

the upper and lower 0.1±inch guard bands and any

 

human readable data).

 

Height adjustments are made in 0.1±inch increments;

 

enter H and a value from 4 to 99 to select height

 

adjustments from 0.4 to 9.9 inches. The default value is

 

0.9±inch.

 

.m is an additional number of dots for the bar code

 

height. (Dots are in the current dot scale.)

BFn;L

Optional parameters for assigning a dynamic bar code

 

data field location on a form and for designating the

 

length of the data field. With these parameters, the

 

actual data for the bar code data field is dynamically

 

provided during the Execute Form Mode; the data is

 

not specified during the Create Form Mode. To use this

 

field, perform the following steps:

 

a.

Enter BF.

 

b.

Replace n with a number ranging from 1 to 255

 

 

to identify the bar code field. The SR and SC

 

 

parameters specify the exact location of the bar

 

 

code field identified by n.

 

c.

Replace L with a number equaling the total

 

 

number of characters in the field. (The actual

 

 

data provided dynamically during the Execute

 

 

Form Mode can be less than L.)

 

d.

The information for the data field is entered

 

 

dynamically during the Execute Form Mode.

 

 

(Refer to ªExecute Form: Dynamic Bar Code

 

 

Dataº on page 4±55 in the ªCommandsº

 

 

chapter.) Do not use the data field parameter to

 

 

enter data when the BFn;L parameters are used.

 

 

However, refer to the data field description for

 

 

available characters.

DARK

Optional parameter to produce darker looking bar

 

codes. Enter DARK. Refer to ªDark Printingº on page

 

4±10 for more information.

Bar Codes

5±81