3M MP8747, MP8746 manual Messages/Solutions, Error Message Displays Cause Solution

Models: MP8747 MP8746

1 44
Download 44 pages 63.2 Kb
Page 28
Image 28

Section 7: Troubleshooting

Messages/Solutions

 

Error Message Displays

Cause

Solution

 

 

 

 

 

NO INPUT IS DETECTED

The projector is not detecting a signal.

Check cable connections to input device. If input device

 

ON **

 

not connected to this input mode, switch to next mode.

 

 

 

 

 

SYNC IS OUT OF RANGE

The horizontal frequency of input signal

Switch projector to correct resolution.

 

ON **

exceeds projector capability.

See Appendix.

 

 

 

 

 

CHANGE THE LAMP.

Nearing end of normal lamp operating time.

Change the projector lamp and reset the lamp operation

 

AFTER REPLACING

 

hours to zero. The message clears automatically after 3

 

LAMP, RESET THE LAMP

 

minutes, and appears each time power is turned on until

 

TIME.

 

lamp is changed.

 

 

 

 

 

CHANGE THE LAMP.

Remaining lamp operation time = 20 hours

Change the projection lamp and reset the lamp operation

 

AFTER REPLACING

or less.

hours to zero. The message clears automatically after 3

 

LAMP, RESET THE LAMP

*Indicates number of hours until power turns

minutes, and appears each time power is turned on until

 

TIME.THE POWER WILL

off automatically.

lamp is changed.

 

TURN OFF AFTER ** HR.

 

 

 

 

 

 

 

CHANGE THE LAMP.

Normal lamp operating time has expired.

Change the projector lamp and reset the lamp operation

 

(blinking)

Safety feature shuts projector down after 10

hours to zero.

 

 

minutes.

 

 

 

 

 

 

CHECK THE AIR FLOW.

The internal temperature has risen.

Switch power OFF and let projector cool for 20 minutes.

 

 

 

Check the following and switch ON again.

 

 

 

• Are ventilation openings dirty or blocked?

 

 

 

• Is air filter dirty or blocked?

 

 

 

• Is ambient temperature over 35°C (95°F)?

 

 

 

 