Section 6: Lamp

Lamp

The following symptoms may indicate that the lamp needs to be replaced:

LAMP indicator lights up red.

“CHANGE THE LAMP” message appears on the screen.

Display Lamp Operation Hours

To determine the lamp operation hours:

1.While the projector is running, press and hold the TIMER button on the remote control for three seconds.

2.The operating time of the lamp will be displayed at the bottom of the screen. The message

“CHANGE THE LAMP, AFTER REPLACING LAMP RESET THE LAMP TIMER” will appear after the lamp has reached the end of the normal lamp life. The message “POWER WILL TURN OFF AFTER 20 HOURS” will appear when 20 or less lamp hours remain. The number of hours left until shutdown will decrease until 0 hour is reached, then power will turn off automatically.

Note: After normal lamp operating time has expired, the projector will only run for 10-minute intervals when restarted until the lamp is replaced and the lamp timer is reset. The message “CHANGE THE LAMP” will blink at projector startup to remind you to change the lamp.

Reset Lamp Hours

The lamp operation hours must be reset after changing the lamp. When the lamp has been replaced after the LAMP indicator is red, or the CHANGE THE LAMP” message is displayed, you must complete the folowing within 10 minutes after switching on the power. Otherwise, the power will automatically shut down after 10 minutes.

1.To display the total lamp hours, press the RESET button on the projector or the TIMER button on the remote control and hold for three seconds. The “LAMP xxxx hr” message will display at the bottom of the screen.

2.To reset the lamp timer, press the RESET button on the projector or MENU button on the remote while the lamp hours are displayed. The lamp hour reset message will display. Use the left-arrow button on the remote control or the Menu Disk Pad button on the projector to select 0, and wait until the timer display has cleared.

© 3M IPC 2000

3MPersonal Projector MP8746/MP8747

25

 

 

 

Page 25
Image 25
3M MP8746, MP8747 manual Display Lamp Operation Hours, Reset Lamp Hours