Technical Appendix

RS-232 Communication

1.Turn off the projector and computer power supplies and connect with the RS-232C cable.

2.Turn on the computer power supply and, after the computer has started up, turn on the

projector power supply.

Projector

Computer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

CD

 

 

 

 

CONTROL Terminal

2

2

RD

 

 

 

 

3

3

TD

RS-232C jack

 

 

 

 

 

 

 

 

 

 

 

 

4

4

DTR

D-sub 15-pin shrink jack

D-sub 9-pin

5

5

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

 

SELO 6

6

DSR

1

2 3

4

5

 

RTS 7

7

RTS

 

10

9

8

7

6

8

8

DTS

6

7

8

9

15

14

13 12

11

 

 

9

9

RI

 

 

 

 

 

 

 

 

 

 

GND 10

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

RD 13

 

 

 

 

 

 

 

 

 

 

 

 

TD 14

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

Communications Setting 19200bps, 8N1

1 Protocol

Consist of header (7 bytes) + command data (6 bytes).

2 Header

BE + EF + 03 + 06 + 00 + CRC_low + CRC_high

CRC_low: Lower byte of CRC flag for command data.

CRC_high: Upper byte of CRC flag for command data.

3 Command data

byte_0

 

byte_1

byte_2

 

byte_3

byte_4

byte_5

 

 

 

 

 

 

 

 

Action

 

Type

 

Setting Code

 

 

 

 

 

 

 

 

low

 

high

low

 

high

low

high

 

 

 

 

 

 

 

 

 

Action

Classification

Content

 

 

 

 

 

 

 

1

SET

Change setting to desired value.

 

 

 

 

 

 

 

2

GET

Read projector internal setup value.

 

 

 

 

 

 

 

4

INCREMENT

Increment setup value by 1

 

 

 

 

 

 

 

5

DECREMENT

Decrement setup value by 1

 

 

 

 

 

 

 

6

EXECUTE

Run a command.

 

 

 

 

 

 

 

 

 

 

 