Section 7: Troubleshooting

Indicator Lights

POWER

LAMP

TEMP

 

Indicator

Meaning

Indicator Light

Indicator Light

Light

 

 

 

 

 

 

 

 

Lights orange

Turns off

Turns off

Standby status

 

 

 

 

Blinks green

Turns off

Turns off

Warming up. Wait.

 

 

 

 

Lights green.

Turns off.

Turns off.

Operation status.

 

 

 

 

Blinks orange.

Turns off.

Turns off.

Cool down.

 

 

 

 

 

 

 

The lamp does not light.

Lights red.

Lights red.

Turns off.

Wait approx. 20 minutes before turning on power again. If

indicator still lights, the lamp may have failed. Replace

 

 

 

 

 

 

lamp.

 

 

 

 

 

 

 

A lamp has not been inserted or the lamp cover is

 

 

 

missing. Turn off projector, disconnect power and wait 45

Lights red.

Blinks red.

Turns off.

minutes for projector and lamp to fully cool. Replace lamp

 

 

 

and/or lamp cover door, then re-connect power and turn

 

 

 

on projector again.

 

 

 

 

 

 

 

The cooling fan is not operating. Switch power off, and

Lights red.

Turns off.

Blinks red.

wait for 20 minutes until the equipment cools. Check to

see if air filter or ventilation openings are blocked. Clear

 

 

 

 

 

 

any obstructions.

 

 

 

 

 

 

 

Internal overheating.Turn off projector, disconnect power,

Lights red.

Turns off.

Lights red.

and let cool for 20 minutes.Check to see if air filter or

 

 

 

ventilation openings are blocked. Clear any obstructions.

 

 

 

 

© 3M IPC 2000

3MPersonal Projector MP8746/MP8747

29

 

 

 

Page 29
Image 29
3M MP8746, MP8747 manual Indicator Lights, Power Lamp Temp