Comments The Incremental Alphanumeric Fixed Data Fields command is a revised

version of the standard IGP/PGL alphanumeric command, but it does not

replace the standard alphanumeric command.

~CREATE;TEST;288

(Enters Create Form mode)

VDUP;3;6

(Repeat alpha string)

ALPHA

(Alpha command)

I;6;5;4;4;±00001;*12345*

 

STOP

(Ends Alpha command)

VDUP;OFF

 

END

(Terminates Create Form mode)

~EXECUTE;TEST

(Prints form)

~NORMAL

 

4±24