Corner Errors

30CORNER starting column SC out of bounds

The left (starting) column specified by the third parameter in the corner command places the corner outside the form boundaries.

31CORNER starting row SR out of bounds

The upper (starting) row of the corner specified by the second parameter in the corner command will place the corner outside the boundaries of the form.

32CORNER ending column EC out of bounds

The right (ending) column specified by the fifth parameter in the corner command places the corner outside the form boundaries.

33CORNER ending row ER out of bounds

The lower (ending) row of the corner specified by the fourth parameter in the corner command will place the corner outside the boundaries of the form.

34CORNER horizontal length HL out of bounds

The length of the horizontal arms of the corner specified by the seventh parameter in the corner command will cause parts of the corner to extend outside the form boundaries.

35CORNER vertical length VL out of bounds

The length of the vertical arms of the corner specified by the sixth parameter in the corner command will cause parts of the corner to extend above or below the boundaries of the form.

36CORNER format or delimiter error in input parameters

Some type of format or delimiter error was detected in the parameters of the corner command. This error is usually caused by one or more of the following:

a.A missing semicolon;

b.A colon in place of a semicolon;

c.Too many or too few parameters in the command string;

d.Alpha characters instead of numeric characters in the parameters.

37Insufficient memory to store the CORNER

No more room in the IGP/PGL memory exists for another corner. The rest of the corner commands are flushed until the Stop command is found. Processing will then continue normally. To create space in the IGP/PGL memory, delete forms with corner elements that are no longer required.

8±6

Error Codes

Page 338
Image 338
Printronix ThermaLine Series manual Corner Errors