Return to default calibration
Returning to the default calibration sets all the corrections made by the paper advance calibration to zero. To return to the default paper advance calibration value, you must reset the calibration.
1.Press the Menu key to return to the main menu and select the Image Quality Maintenance menu
icon , then Paper advance calibration > Reset paper advance
.
2.Wait until the front panel displays the operation has completed successfully before pressing the back key to return to the main menu.
Paper issues
ENWW | Recalibrate the paper advance 157 |