PTX_Setup Command Description

Purpose Enables the host to control PSA printer resources common to all emulations.

Mode All modes (Normal, Quiet, etc.)

Format (cc) PTX_SETUP

<category±> [<parameter;value:> ...<parameter;value:><parameter;value:>.

:

:

<category±> [<parameter;value:> ...<parameter;value:><parameter;value:>.

PTX_END

(cc)

The Special Function Control Character.

 

This cc is NOT the PGL SFCC. It is the ªsetupº SFCC

 

and is set under the Maint/Misc configuration menu.

PTX_SETUP

The trigger command. Must appear in capital letters.

 

Once the trigger is detected, all unprintable characters

 

and spaces (i.e., characters less than 21 hex) are

 

ignored.

<category ± >

This selects which category or type of command is

 

being entered: CONFIG, DISK_IO, ENGINE,

 

FORMAT or TEST_CHK. All categories must appear

 

in capital letters and must be followed by a dash (±).

<parameter;value:> Parameter and value pair for the current category. See the listing of categories, valid parameters and ranges of values beginning on page 3±4. The parameter and value must be separated by a semicolon (;) and must be terminated by either a colon (:) or a period (.).

The colon signifies that more parameter/value pairs for the current category are to follow; therefore, more than one parameter/value pair may be given for the current category. The period denotes the end of parameter/ value pairs for the given category.

Parameter/value pairs must not exceed 25 characters with the semicolon and terminator included.

3±2

PTX_Setup

Page 40
Image 40
Printronix ThermaLine Series manual PTXSetup Command Description, Ptxend, Ptxsetup