Vertical Line Errors

10VERTical line starting column SC out of bounds

The column specified by the second parameter in the vertical line command places the vertical line outside the form boundaries.

11VERTical line starting row SR out of bounds

The upper (starting) row of the vertical line specified by the third parameter in the vertical line command places the vertical line outside the boundaries of the form.

12VERTical line ending row ER out of bounds

The lower (ending) row of the vertical line specified by the fourth parameter in the vertical line command places the vertical line outside the boundaries of the form.

13VERTical line format or delimiter error

Some type of format or delimiter error was detected in the parameters of the vertical line command. This error is usually caused by one or more of the following:

a.A missing semicolon;

b.A colon in place of a semicolon;

c.Too many or too few parameters in the command string;

d.Alpha characters instead of numeric characters in the parameters.

14Insufficient memory to store the VERTical line

No more room in the IGP/PGL memory exists for another vertical line. The rest of the vertical line commands are flushed until the Stop command is found. Processing will then continue normally. To create space in the IGP/PGL memory, delete forms with vertical line elements that are no longer required.

15VERTical line starting row SR > ending row ER

The upper (starting) row parameter of the vertical line command is greater than or equal to the lower (ending) row parameter.

16VERTical line thickness LT error

The thickness of the vertical line specified by the first parameter in the vertical line command is incorrect. This error is usually caused by specifying a thickness of zero.

17±19 Not defined.

8±4

Error Codes

Page 336
Image 336
Printronix ThermaLine Series manual Vertical Line Errors