Printronix ThermaLine Series manual ±2/5 Command Format

Models: ThermaLine Series

1 412
Download 412 pages 39.7 Kb
Page 218
Image 218

I±2/5 Command Format

BARCODE

I±2/5 [CD]; [VSCAN;] [MAG;] [Hn[.m];] [BFn;L;] [DARK;] SR; SC [(D)data field(D)]

[PDF [;LOC] [;FONT]]

STOP

I±2/5 German Command Format

BARCODE

I25GERMAN; [VSCAN;] [MAG;] [Hn[.m];] [BFn;L;] [DARK;] SR; SC [(D) data field (D)]

[PDF [;LOC] [;FONT]]

STOP

BARCODE

The Bar Code command; enter BARCODE.

I±2/5 CD

Designates bar code type Interleaved 2/5; enter I±2/5.

 

To calculate and plot the optional modulo±10 check

 

digit with the bar code symbol automatically, enter

 

CD. For the German variation of the bar code, enter

 

I25GERMAN, instead of I-2/5(the checksum digit is

 

always automatically calculated for German I-2/5).

VSCAN

Optional parameter to orient the bar code structure

 

vertically. To select a vertical bar code, enter VSCAN.

 

If VSCAN is not entered, the bar code is oriented

 

horizontally.

MAG

Optional parameter to magnify (horizontally expand)

 

the bar code symbol. The magnification default value

 

is X1. For the German variation of the bar code, the

 

default magnification is X1A. As required for

 

scanning, enter a magnification value to increase the

 

magnification. Increasing the magnification adjusts

 

printed character density. You can also use XR or XRD

 

as defined on page 5±4.

5±80

Bar Codes

Page 218
Image 218
Printronix ThermaLine Series manual ±2/5 Command Format, I25GERMAN Vscan MAG Hn.m BFnL Dark SR SC D data field D